9-3. 0-Adjust Setting Function
This function allows for automatic zeroing of the incident light intensity.
* The threshold value is not linked to this function, so that after carrying out zero adjustment, be sure to reset the
threshold value.
Press the
MODE key 5 times.
Turn the Jog switch 5 times
toward the ‘
’ direction.
Turn the Jog switch once
toward the ‘
’ direction.
Press the
Jog switch.
Press the
Jog switch.
Press the
Jog switch.
Press the Jog switch to zero
the incident light intensity.
Turn the
Jog switch.
0-Adjust
ON
0-Adjust
OFF
Press the
MODE key once.
Press the
MODE key once.
The digital display will quickly
blink to confirm the setting.
1
Press the [MODE key] 5 times to select ‘PRO mode’.
3
Press the [Jog switch] to enter the ‘code setting’ state.
2
Turn the [Jog switch] 5 times toward the ‘
’ direction, to
select ‘PRO5 mode’.
9
If the [MODE key] is pressed once, the amplifier will return to
‘PRO5 mode’.
0
Press the [MODE key] once, the amplifier will return to ‘RUN
mode’ (normal sensing operation).
4
Turn the [Jog switch] once toward the ‘
’ direction, to enter
the ‘0-Adjust setting’ state.
7
When zero adjustment has been completed
n
The current incident light intensity will be displayed.
When zero adjustment has not been completed or has been
cancelled
n
The amplifier will return to the ‘0-Adjust setting’ state.
8
If the [Jog switch] is pressed to set the desired incident light
intensity to ‘0’, the digital display (red) will quickly blink,
confirming the zero adjustment.
Note: When zero adjustment is performed with the digital
display showing the 2,000 digits or greater, –1,999
digits or less will not be displayed.
6
If the [Jog switch] is turned, 0-Adjust setting (red) will blink
on the digital display.
•
When setting zero adjustment
n
Select ‘SET’, then press the [Jog switch].
•
When not performing zero adjustment or when canceling a
‘0-Adjust setting’ that has already been set
n
Select ‘OFF’, then press the [Jog switch].
5
If the [Jog switch] is pressed, the current setting (red) will be
displayed.
* The factory setting is ‘ ’.
49
Ramco National
(800) 280-6933
www.panasonicsensors.com