PRO3 Mode
7-1. PRO3 Mode Functions and Settings
7
: Data Bank Load Function
: Data Bank Save Function
This function allows settings from the data bank to be selected and then loaded.
This feature allows settings to be changed quickly at times of reconfiguration, etc.
You can select whether the settings for only one amplifier are loaded or the
settings for all amplifiers on the right side that are connected via optical
communication are loaded all in a single step.
Refer to p. 39 for setting procedure
Refer to p. 40 for setting procedure
This function saves amplifier settings.
Up to 3 sets of settings can be saved in ‘ ’, ‘ ’ and ‘ ’.
You can select whether the settings for only one amplifier are saved or the
settings for all amplifiers on the right side that are connected via optical
communication are saved all in a single step.
Data bank
PRO3 mode can load settings from the data bank and can save settings to the data bank.
The LS-400 series incorporates an internal memory for storing setting.
Three different sets of settings can be stored within the data banks, in channels 1 ( ) to 3 ( ).
These settings will not be deleted, unless they are intentionally overwritten by the data bank save setting
function.
Setting within the data bank will not be deleted, even when a reset is performed using the ‘9-4. Setting Reset
Function’ from ‘PRO5 Mode’ on p. 50.
Optical communication
When the collective data bank load / save function or copy function is used via optical communication, loading /
saving or copy of the setting can be carried out only to the amplifiers (sub units) connected on the right side of
the amplifier (main unit). However, if the amplifier (sub unit) is being connected (the indicator blinks), PRO mode
is being set or the transmission change to permit / not to permit function is set to ‘not to permit’, loading / saving
or copy is not carried out. Furthermore, the sensing operation stops during optical communication.
(
(
To copy the same settings to the 4th and subsequent channels:
Use the 4-channel data bank load / save function and the copy function.
To copy the same settings to the 1st and subsequent channels:
Use the 1-channel single step data bank load / save function and the copy function.
1CH 2CH 3CH 4CH 5CH 6CH 7CH 8CH 9CH 10CH 11CH 12CH 13CH 14CH 15CH 16CH
Example: When 16 amplifiers are connected in the side-by-side configuration
1CH 2CH 3CH 4CH 5CH 6CH 7CH 8CH 9CH 10CH 11CH 12CH 13CH 14CH 15CH 16CH
Communication direction
* The incident light intensity display changes while
optical communication is in progress.