4.5.6 Inspection
Execution
The ways of inspection execution
Internal trigger: ON
Inspection is automatically performed by switching to RUN mode.
Internal trigger: OFF
After switching to RUN mode, input the TRIGGER signal to external devices or
press the TRIGGER button.
Inspection judgement results
Judgement results are output to the parallel ports of OUT1 to OUT3 as the table shown below.
Judgement results
OUT3
OUT2
OUT1
OK
Point was detected, and the detected peak distance is
within the “base di/- allowable range.
OFF
OFF
ON
NG Except those above
OFF
OFF
OFF
Checking the measured data
When executing an inspection in RUN mode, you can check the X- and Y- directional distance of the
detected edge. But you cannot display all the measurement data at the same time.
Display
data
switch
To the Top
Upper line: Product type number and type of data
Data type: X / Y / TIME
•
X: X-directional distance of the detected point
•
Y: Y-directional distance of the detected point
•
TIME: Calculation time
Lower line: Data value
•
X-/Y-directional distance: Up to four digits* including
the numbers under the decimal point
(The digits under the decimal point differs depending
on the type of device.)
When any point is not detected, the screen display is
as the figure shown right.
•
Calculation time: Less than two digits
, slightly differs depending on the position of the
detected point
Product
type
switch
The <3>, <4> and <5> buttons:
Changes the product types
Once the product types are
switched,OUT1 to 3 are reset.
*Data range
Type
Data
ANE2000
ANE2010
ANE2020
ANE2030*
X
0 to 2.00
0 to 10.00
0 to 30.00
0 to 80.00
Y
0 to 1.60
0 to 8.00
0 to 25.00
0 to 70.00
*The view range changes within the range of 70 x 56 to 100 x 80 depending on the installation position of
ANE2030, but the position data are converted into mm based on the range of view 80 x 70. Therefore, if you use
the unit out of the view range 80 x 70, the position data differs from the actual size.
Parallel input/output timing chart: Page 102
80
Содержание LightPix AE20
Страница 1: ...http www nais e com vision Panasonic the new name for Matsushita Electric Works Ltd User s Manual ...
Страница 8: ...Chapter 1 Overview of Light Pix AE20 1 ...
Страница 12: ...Chapter 2 Names and Functions of Parts 5 ...
Страница 18: ...Chapter 3 Installation and Wiring 11 ...
Страница 36: ...Chapter 4 Inspection Applications 29 ...
Страница 106: ...Section 5 Parallel Communication 99 ...
Страница 113: ...Section 6 RS 232C Communication 107 ...
Страница 138: ...Section 7 About AETOOL and GT11 133 ...
Страница 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...
Страница 148: ...Mounting plate Operation unit 144 ...
Страница 149: ...Finder unit 145 ...
Страница 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...
Страница 151: ...ARCT1F406E 200505 P 2005 ...