4.1.2 Inspection
Time
Inspection time refers to the total time required for the following four inspections.
1 Exposure time
0.03 - 50.00 ms, set the exposure time in TEACHING mode
2 Transfer time
4 ms: Fixed
3 Computation
time
Differs depending on the application and “inspection speed”
setting
(Set the inspection speed in CONFIGURATION mode.)
Inspection
Time
4 Display time
300 ms
Available only if the image is displayed on the finder unit in RUN
VIEW mode
Standard computation time (internal trigger:OFF)
Inspection speed settings
Application
High
Middle
Low
Color Area
10 (No SPEED setting function)
Color
Judgement
20 50 150
Color Pattern Matching *
100
200
500
Edge
10 15 20
Peak *
10 (No SPEED setting function)
Measurement
15 20 30
Unit: ms
Internal trigger: ON
At least 30ms is required for inspection.
(If the inspection time exceeds 30ms, it will become equal to the one required for internal trigger OFF.)
For example, if exposure time for Color Judgement = 5 ms,
Internal
trigger
Inspection
time
Explanation
OFF
19 ms
= Computation time (10) + exposure time (5) + transmission time (4)
ON
30 ms
If the total time is less than 30ms when internal trigger is ON, the
device is forced to wait until 30ms.
•
Computation time for Color Pattern Matching slightly differs depending on the measurement
condition and inspection position. The conditions of computation time above is as follows:
Template size: 64 x 48 pixels
•
After changing product types, it takes approximately 50ms longer than normal inspection time for
the first inspection.
•
If you execute inspection monitoring images and measurement results with AETOOL, it takes 0.6
to 1.2 second longer than the inspection time shown in the table above.
31
Содержание LightPix AE20
Страница 1: ...http www nais e com vision Panasonic the new name for Matsushita Electric Works Ltd User s Manual ...
Страница 8: ...Chapter 1 Overview of Light Pix AE20 1 ...
Страница 12: ...Chapter 2 Names and Functions of Parts 5 ...
Страница 18: ...Chapter 3 Installation and Wiring 11 ...
Страница 36: ...Chapter 4 Inspection Applications 29 ...
Страница 106: ...Section 5 Parallel Communication 99 ...
Страница 113: ...Section 6 RS 232C Communication 107 ...
Страница 138: ...Section 7 About AETOOL and GT11 133 ...
Страница 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...
Страница 148: ...Mounting plate Operation unit 144 ...
Страница 149: ...Finder unit 145 ...
Страница 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...
Страница 151: ...ARCT1F406E 200505 P 2005 ...