5.1 Operations through Parallel Communication
5.1.1 Using Input Signals from External Devices
Inputting signals to each cable from external devices enables the LightPixAE20 to perform the following
operations.
Input
Operation
Used signal
Executes an inspection
TRIGGER signal
Switches product types
TYPE1 to 3 signals
Switches to TEACHING mode
TEACH signal
Input:
Operations triggered
by inputting signals
from external devices
Teaching
(Switches modes and executes a teaching)
TEACH TRIGGER signal
5.1.2 Output
Signals from the LightPix
The data output from the LightPixAE20 when executing a reading operation
After executing an inspection, the following signals are output to the parallel ports of OUT1 to OUT3. The
output signals differ depending on the application and result.
Colro Area
Judgment Results
OUT3 OUT2 OUT1
OK Within the range
OFF
OFF
ON
NG Out of the range
OFF
OFF
OFF
Color Judgment
Color (Product Type) No.
OUT3 OUT2
OUT1
0
N/A = All NG
OFF
OFF
OFF
1 OFF
OFF
ON
2 OFF
ON
OFF
3 OFF
ON
ON
4
ON
OFF
OFF
5
ON
OFF
ON
6
ON
ON
OFF
7
ON
ON
ON
100
Содержание LightPix AE20
Страница 1: ...http www nais e com vision Panasonic the new name for Matsushita Electric Works Ltd User s Manual ...
Страница 8: ...Chapter 1 Overview of Light Pix AE20 1 ...
Страница 12: ...Chapter 2 Names and Functions of Parts 5 ...
Страница 18: ...Chapter 3 Installation and Wiring 11 ...
Страница 36: ...Chapter 4 Inspection Applications 29 ...
Страница 106: ...Section 5 Parallel Communication 99 ...
Страница 113: ...Section 6 RS 232C Communication 107 ...
Страница 138: ...Section 7 About AETOOL and GT11 133 ...
Страница 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...
Страница 148: ...Mounting plate Operation unit 144 ...
Страница 149: ...Finder unit 145 ...
Страница 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...
Страница 151: ...ARCT1F406E 200505 P 2005 ...