17-29
17.4.13 System Operation Setting Area
This area is used to switch the operation of the positioning unit.
Bank
Offset
address
Name
Descriptions
Default
value
Setting
range
Unit
00H
384H
AMP control
mode
Executes operations such as changing the
parameters of AMP (A4N/A5N/A6N).
The following operations can be executed by
changing this area to "AMP control enable".
- Reading AMP parameters
- Writing AMP parameters
- Saving AMP parameters (EEPROM write)
- Resetting AMP (Restart)
When this area is set to 1H (AMP control
enable), the settings of "Operating direction"
and "Limit connection" which are parameters
of each axis of positioning unit RTEX are
invalid. After completion of operation, always
set this area to 0H (AMP control disable).
00H: Set AMP parameter
01H: Not set AMP parameter
0
0 to 1
-
389
H
Deceleration
stop operation
Specify the operation when setting the
deceleration stop request signal to "Active"
(from OFF to ON).
0: Deceleration stop
When performing the repeat operation, stops
after reaching E point that is targeted for the
repeat operation.
1: Pause
- Performs the deceleration stop, and restarts
the positioning operation when turning
"Deceleration stop request signal" to OFF
from ON.
- Also, performs the same operation as the
deceleration stop in all states except during
the positioning operation.
- When performing the repeat operation, stops
after reaching E point that is targeted for the
repeat operation, and restarts the
positioning operation when turning
"Deceleration stop request signal" to OFF
from ON.
- If the system stop or emergency stop is
executed during the pause, the pause will be
cancelled. The operation will not restart
even if turning "Deceleration stop request
signal" to OFF from ON.
0
0 to 1
-
Содержание FP2 Positioning Unit RTEX
Страница 1: ......
Страница 6: ...iv ...
Страница 14: ...xii ...
Страница 15: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Страница 21: ...Chapter 2 Parts and Functions ...
Страница 22: ...2 2 2 1 Parts and Functions FPΣ Positioning Unit RTEX FP2 Positioning Unit RTEX ...
Страница 24: ...2 4 ...
Страница 25: ...Chapter 3 Wiring ...
Страница 27: ...3 3 3 2 Network Connector RJ45 plug is connected to the network connector Pins of RJ45 plug Connecting diagram ...
Страница 31: ...Chapter 4 Power On Off and Items to Check ...
Страница 36: ...4 6 ...
Страница 37: ...Chapter 5 4BPreparation For Operation ...
Страница 45: ...Chapter 6 5BI O Allocation ...
Страница 53: ...Chapter 7 6BSetting Tool Configurator PM ...
Страница 83: ...7 31 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Страница 102: ...7 50 ...
Страница 103: ...Chapter 8 7BAutomatic Operation Position Control ...
Страница 118: ...8 16 ...
Страница 119: ...8 17 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Страница 141: ...Chapter 9 8BManual Operation JOG Operation ...
Страница 146: ...9 6 ...
Страница 147: ...Chapter 10 9BManual Operation Home Return ...
Страница 155: ...Chapter 11 10BManual Operation Pulser Operation ...
Страница 159: ...Chapter 12 11BStop Functions ...
Страница 162: ...12 4 ...
Страница 163: ...Chapter 13 12BSupplementary Functions ...
Страница 177: ...13 15 Sample program When reading AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Страница 179: ...13 17 Sample program When writing AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Страница 183: ...Chapter 14 Precautions During Programming ...
Страница 187: ...Chapter 15 Errors and Warnings ...
Страница 212: ...15 26 ...
Страница 213: ...Chapter 16 Troubleshooting ...
Страница 214: ...16 2 16 1 Cannot Communication With AMP ...
Страница 215: ...Chapter 17 Specifications ...
Страница 275: ...Chapter 18 Dimensions ...
Страница 276: ...18 2 18 1 FPSigma Positioning Unit RTEX ...
Страница 277: ...18 3 18 2 FP2 Positioning Unit RTEX ...
Страница 278: ...18 4 ...
Страница 279: ...Chapter 19 Sample Programs ...
Страница 283: ...19 5 ...
Страница 286: ...19 8 ...
Страница 288: ......