Panasonic Digital Business System - Programming Manual
April 1997
Issue 15
81
E&M paging release timer
3.1
[NET PAG RELEASE]
FF2-2#-(1-3)#-5#-(0-6)#
(1-3)#
(0-6)#
E&M trunk group
0#: Not used
1#: 30 seconds
2#: 60 seconds
3#: 90 seconds
4#: 120 seconds
5#: 150 seconds
6#: 180 seconds
Sets the time in seconds to release the E&M circuit when paging. This timer only takes effect if the
paging call goes unanswered and prevents the circuit from being kept unnecessarily busy.
E&M minimum pause
3.1
[MIN INTERDIGIT]
FF2-2#-(1-3)#-6#-(0-7)#
(1-3)#
(0-7)#
E&M trunk group
0#: 300 msec
1#: 400 msec
2#: 500 msec
3#: 600 msec
4#: 700 msec
5#: 800 msec
6#: 900 msec
7#: 1000 msec
Sets the minimum pause between dial pulses when making an E&M call. The default setting is for
DBS to DBS connection and may require adjustment when the remote system is not a DBS.
E&M return confirmation monitor
3.1
[RELEASE ACK TIM]
FF2-2#(1-3)#-7#-(0-7)#
(1-3)#
(0-7)#
E&M trunk group
0#: 1 second
1#: 2 seconds
2#: 3 seconds
3#: 4 seconds
4#: 5 seconds
5#: 6 seconds
6#: 7 seconds
7#: 8 seconds
Sets the interval between sending out the release signal to the other party and receiving the
release acknowledge signal after ending an internal call via the E&M Card.