Panasonic Digital Business System - Programming Manual
April 1997
Issue 15
60
Night Mode - DDI Extension / Group Setting
CPC-EX 2.1
FF1 6# 5# (1-200)# 7# (NNNN)#
This step stores the extension or group number to be rung by each DDI stored in the step FF1 6#
5# (DDI)# 1#. There is a setting for each DDI number. The locations 1-144/1-200 correspond to
the locations in the other DDI steps. The format of data to be stored is determined by the setting
made for each entry in FF1 6# 5# 2# as follows:
FF1 6# 5# 6#
Data format
0
extension number
1
1-50 group number
2
extension number on remote system
3
no setting required - all calls to operator extension
Related Steps: FF1 6# 5# (DDI)# 1# (N - NNNNNN)#
FF1 6# 5# (DDI)# 6# (0-3)#
Night Mode - DDI Busy / No Answer Mode
CPC-EX v2.1
FF1 6# 5# (1-200)# 8# (0-2)#
0# To Operator Extension
1# Terminate Call
2# To Alternative Destination Extension In Step FF! 6# 5# 5#
In Day Mode, if the DDI destination is busy or not answered at the extension or group specified in
the DDI table, the call can be routed to the Operator Extension, specified transfer extension ( FF1
6# 5# 5# ) or terminated
Related Step:
FF1 6# 5# 9# - Night Mode - DDI Transfer Telephone Setting
Night Mode - DDI Transfer Telephone Setting
CPC-EX v2.1
FF1 6# 5# (1-200)# 9# (NNNN)#
NNNN# Extension or Group Virtual Extension Number
In Day Mode, if an incoming DDI call is not answered it can be routed to a specified extension or
group. Each DDI can be given its own alternative destination.
Related Step:
FF1 6# 5# 8# - Night Mode - DDI Busy / No Answer Mode