Panasonic Digital Business System - Programming Manual
April 1997
Issue 15
63
DASSII Answer Confirm Timer
CPC-EX v1.5
FF1 6# 6# 5# (1-15)#
1# 0.5 Sec.
2# 1 Sec.
3# 1.5 Sec.
4# 2 Sec.
5# 3 Sec.
6# 4 Sec.
7# 5 Sec.
8# 6 Sec
9# 8 Sec.
10# 10 Sec.
11# 12 Sec.
12# 14 Sec.
13# 16 Sec
14# 20 Sec
15# 25 Sec
For DASSII connections, this is the time the DBS will wait for acknowledgment of an Initial Service
Request Message from the network when originating a call. This step has been moved from FF1
6# 3# 3#.
E-ISDN Red Alarm Detection Timer
CPC-EX v1.5
FF1 6# 7# 1# (1-15)#
1# 1 Sec.
2# 1.5 Sec.
3# 2 Sec.
4# 2.5 Sec.
5# 3 Sec.
6# 3.5 Sec.
7# 4 Sec.
8# 4.5 Sec
9# 5 Sec.
10# 5.5 Sec.
11# 6 Sec.
12# 6.5 Sec.
13# 7 Sec
14# 7.5 Sec
15# 8 Sec
Used for E-ISDN connections, this is the length of time a red alarm condition has to be present
before the DBS will indicate a red alarm condition.