Panasonic Digital Business System - Programming Manual
April 1997
Issue 15
49
3.1Khz Audio Call - Incoming Ring
CPC-EX v1.5
FF1 6# 1# 10# (0-1)#
0# Rings To Operator
1# Rings As An Incoming Call
If a 3.1 KHz Audio call is received by the system and is not assigned an answer position it can be
directed to the Operator extension or handled as a normal incoming call as required by the system
configuration.
DDI Number Output Setting
ISDN 1.0
FF1 6# 2# 1# (0-1)#
0# Not Output
1#
Output
The DDI number which was dialled by the incoming caller can be output to the call logger if
required. It appears in the dialled number field after the incoming ring time.
Other Party’s Number Output - Incoming Call
ISDN 1.0
FF1 6# 2# 2# (0-1)#
0# Not Output
1#
Output
The calling party’s OLI can be output to the call logger.
Other Party’s Number Output - Outgoing Call
ISDN 1.0
FF1 6# 2# 3# (0-1)#
0# Not Output
1#
Output
The called party’s TLI can be output to the call logger.
Sub-address Number Output To The Call Logger
CPC-EX v1.5
FF1 6# 2# 4# (0-1)#
0# No Output To Call Logger
1# Incoming Sub-address Number Sent To Call Logger
Incoming sub-address numbers can be sent to the call logging system if required.