Panasonic Digital Business System - Programming Manual
April 1997
Issue 15
71
Network Mode Setting
3.1
[NETWORK TYPE]
FF1-9#-1#-(0-4)#
0#: Standalone
1#:
Networked (Route access code 2)
2#:
Networked (Route access code 3)
3#:
Networked (Route access code 4)
4#:
Networked (Route access code 5)
Sets the DBS as a standalone system or network node. This step also assigns the route access
code to a networked system.
No Answer Timer
3.1
[NO ANSWER TIMER]
FF1-9#-2#-(1-5)#
1#: 20 sec
2#:
30 sec.
3#:
40 sec.
4#:
50 sec.
5#:
60 sec.
Sets the time in seconds to cut off a call across an E&M circuit if the recipient end of the private
line does not answer. This setting applies to private line calls only.
Route Access Code 2
3.1
[R.A.C.2 NUMBER]
FF1-9#-3#-(0-3)#
0#: Local
1#:
Private line group 1
2#:
Private line group 2
3#:
Private line group 3
Assigns the private line group to use for route access code (RAC) 2. If the system is itself
allocated RAC 2, set for local. When RAC 2 is used the circuits assigned to the group set here will
be used to access the remote system.