Panasonic Digital Business System - Programming Manual
April 1997
Issue 15
70
PAD Settings
CPC-EX 1.0
FF1 6# 98# (1-31)# (0-30)#
(1-31)#
Connection Type
(0-30)#
Level Adjustment
1#
KTS - DASS
0#
0 dB
2#
SLT - DASS
1#
2 dB
3#
RESERVED
2#
4 dB
4#
Analogue Line - DASS
3#
6 dB
5#
DASS - DASS
4#
8 dB
6# - 9#
RESERVED
5#
10 dB
10#
DASS - KTS
6#
12 dB
11#
DASS - SLT
7#
14 dB
12#
RESERVED
8#
16 dB
13#
DASS - Analogue Line
9#
18 dB
14#
DASS - DASS
10#
20 dB
15# - 18#
RESERVED
11#
22 dB
19#
Analogue Line - Analogue Line 12#
24 dB
20#
Analogue Line - Private Wire
13#
26 dB
21#
RESERVED
14#
28 dB
22#
DASS - Private Wire
15#
30 dB
23#
RESERVED
16#
-2 dB
24#
Private Wire - Analogue Line
17#
-4 dB
25#
Private Wire - DASS
18#
-6 dB
26#
Private Wire - Private Wire
19#
-8 dB
27# - 31#
RESERVED
20#
-10 dB
21#
-12 dB
22#
-14 dB
23#
-16 dB
24#
-18 dB
25#
-20 dB
26#
-22 dB
27#
-24 dB
28#
-26 dB
29#
-28 dB
30#
-30 dB
During conversations involving two lines differences in the line levels can lead to howling. To
prevent this the cross connection levels between the installed line types can be adjusted to
remove the howl. To use these setting the Synchronisation unit VB3668UK must be installed on
the CPC-EX card. The levels can be ad/_ 30 dB using these steps.
ID code-DISA access
2.x
[SET 4DIGIT DATA]
FF1-8#-(0000-9999)#
[CONF]#: Clear data
(0000-9999)#
ID Code
When this step is set the ID code stored must be entered by the caller before the system will
accept extension routing digits from an incoming DISA call.
Note:
To enable remote maintenance, it is necessary to input the remote program access code
separately.
Related step
FF2 1# (00-48)# 20# DISA line setting
This step has been replaced by FF1-4#-3# on CPC-EX v1.0