14 – Error Code
Explanation:
Mid & High Efficiency:
Over Heat Limiter (OHL)
malfunction.
High Efficiency ONLY:
Over heat condition in the venting has triggered the Over
Temp Limit Switch
Diagnostic Checks:
•
Mid & High Efficiency:
OHL
•
High Efficiency ONLY:
Over Temp Limit Switch
OHL DIAGNOSTICS:
Mid Efficiency ONLY:
IF 14 Error Code does NOT display, unit had a loose
connection. IF 14 Error Code IS displayed, continue to
diagnostic chart on next page.
Turn power OFF. Remove and reinsert white
connector “U” on Control Board (white Molex with 2
white wires). Attempt to operate unit again.
1
2
3
High Efficiency ONLY:
IF 14 Error Code does NOT display, unit had
a loose connection.
IF 14 Error Code IS displayed, locate the over
temp switch and continue to diagnostic
chart on next page.
OHL
Over Temp Switch
Содержание PH2-20R OFN
Страница 158: ...158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 159: ...159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 160: ...160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 162: ...162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 163: ...163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 164: ...164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166...
Страница 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167...
Страница 169: ...169 Schematic Disassembly PHH 32ROF PHH 25ROF...
Страница 170: ...170 matic Disassembly PHH 32ROF PHH 25ROF...