10 – Warning Code
Explanation:
The Blower Motor is not creating enough ventilation. The system passed the pre-purge cycle, but detects vent
blockage during normal operation. The unit will continue to operate but may eventually shut down with Error Code 99.
First check your GAS SUPPLY & VENTING; the most common causes for Error Code 10.
Diagnostic Checks:
•
GAS SUPPLY & VENTING
•
Blower Motor
GAS SUPPLY & VENTING
**REFER TO USE & CARE MANUAL**
Make sure you have sufficient fuel for the unit to operate properly.
1.
Gas Type (LP or Natural Gas)
2.
Gas Pressure
3.
Gas Pipe Size
4.
Gas Flex Line Not To Exceed 36” In Length, has the proper ID (Inside Diameter), and correct BTU rating
5.
Gas Regulator
6.
Gas Shut Off Valves
7.
Air In Gas Line
Visually inspect venting for possible blockage and/or recirculation of exhaust.
1.
Approved Venting Materials
2.
Approved Vent Terminations
3.
Vent Lengths
4.
Location Of Vent Termination (Recirculation of exhaust)
5.
Blocked Venting
6.
Venting Not Sealed Properly
Содержание PH2-20R OFN
Страница 158: ...158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 159: ...159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 160: ...160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 162: ...162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 163: ...163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 164: ...164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166...
Страница 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167...
Страница 169: ...169 Schematic Disassembly PHH 32ROF PHH 25ROF...
Страница 170: ...170 matic Disassembly PHH 32ROF PHH 25ROF...