38 |
Page SVC 820 Tankless Gas Trouble Shooting Manual
38
GAS CONTROL VALVE DIAGNOSTICS:
(Igniter Rod DOES spark & NO flame)
Turn power OFF. Remove and reinsert connector “K” on
Control Board.
1
Locate PGFR valve on lower right of unit. Remove and
reinsert Molex connector with red wire and Molex
connector with black wire on PGFR.
Attempt to operate unit again.
Remove and reinsert connector “R” on Control Board.
IF 11 Error Code does NOT display, unit had a loose
connection.
IF 11 Error Code IS displayed, continue to diagnostic chart
on next page.
3
2
4
PGFR
Molex Connectors