84 |
Page SVC 820 Tankless Gas Trouble Shooting Manual
84
76 – Error Code
Explanation:
Communication Fault with Remote Control.
Remote Control is not communicating with Control Board
Diagnostic Checks:
•
Remote Control
•
Wiring
REMOTE THERMOSTAT DIAGNOSTICS
:
Visually inspect Remote Control wiring for damaged or
loose terminals.
1
Turn power OFF. Remove and reconnect Remote Control
wiring terminals at bottom of unit. Attempt to operate
unit again. IF 76 Error Code does NOT display, unit had a
loose connection.
IF 76 Error Code IS displayed, continue to diagnostic chart
on next page.
2
Hot Water Outlet
Cold Water Inlet
Remote Control
Wiring Terminals