SVC 820-Tankless Gas Trouble Shooting Manual Page |
73
73
52 – Error Code Diagnostic Chart
NO
YES
YES
NO
While unit is attempting to go to main
burner, check DC voltage across red wire
#1 and black wire #2 on Connector “R”:
1.5 – 14 DC VOLTS
Is the DC voltage
OK?
Attempt to operate unit again.
If the unit malfunctions due to an Error
Code 52:
Replace Control Board
Is the DC voltage
OK?
While unit is attempting to go to main burner, check
DC voltage across red and black wires at PGFR:
1.5 – 14 DC VOLTS
Attempt to operate unit again.
If the unit malfunctions due to an Error Code 52:
Replace Gas Control Valve
Replace wiring harness for Connector “R”
on Control Board