SVC 820-Tankless Gas Trouble Shooting Manual Page |
77
77
65 – Error Code Diagnostic Chart
YES
NO
YES
YES
NO
While water is flowing and unit is
attempting to ignite; check DC Voltage
across White & Black Wires at
connector “C”:
8 – 16 DC VOLTS
Is the DC voltage
OK?
Attempt to operate unit again.
If the unit malfunctions due to an Error
Code 65:
Replace Control Board
Is the DC voltage
OK?
Turn power to unit OFF then ON again and turn water
flow on. Check DC Voltage across Red & Black Wires
at connector “C”:
8 – 16 DC VOLTS
Turn power to unit OFF then ON again and turn water
flow on. Check DC Voltage across Green & Black
Wires at connector “C”:
4 – 6 DC VOLTS
Attempt to operate unit again.
If the unit malfunctions due to an Error
Code 65:
Replace Control Board
Is the DC voltage
OK?
NO
Attempt to operate unit again.
If the unit malfunctions due to an Error
Code 65:
Replace Control Board
Attempt to operate unit again.
If the unit malfunctions due to an Error
Code 65:
Replace Water Control Valve
Содержание PH2-20R OFN
Страница 158: ...158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 159: ...159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 160: ...160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 162: ...162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 163: ...163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 164: ...164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166...
Страница 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167...
Страница 169: ...169 Schematic Disassembly PHH 32ROF PHH 25ROF...
Страница 170: ...170 matic Disassembly PHH 32ROF PHH 25ROF...