66 – Error Code
Explanation:
Water Bypass Valve malfunction. Hot outlet
water temperature is above or below set point on Remote
Control.
Diagnostic Checks:
•
Water Bypass Valve
WATER BYPASS VALVE DIAGNOSTICS:
•
Turn power OFF. Remove 3 screws for Control Board
mounting bracket. Remove connectors “M”; “T”; &
“G”. Pull Control Board out of way to access Water
Bypass Valve.
Turn power OFF. Remove and reinsert connector “B”
on Control Board. Attempt to operate unit again. IF
66 Error Code does NOT display, unit had a loose
connection.
1
2
3
Visually inspect Water Bypass Valve
wiring harness for loose or damaged
terminals. It is located right of the
Blower Motor; below two copper
pipes. Reassemble unit and continue
to diagnostic chart on next page.
Screws
Blow
er
M
ot
or
Top
of
U
nit
Bo
tto
m
o
f U
ni
t
Water Bypass Valve
Control Board
Bottom of Unit
Содержание PH2-20R OFN
Страница 158: ...158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 159: ...159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 160: ...160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 162: ...162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 163: ...163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 164: ...164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166...
Страница 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167...
Страница 169: ...169 Schematic Disassembly PHH 32ROF PHH 25ROF...
Страница 170: ...170 matic Disassembly PHH 32ROF PHH 25ROF...