80 |
Page SVC 820 Tankless Gas Trouble Shooting Manual
80
71 – Error Code
Explanation:
Gas Control Valve malfunction
Diagnostic Checks: Gas Control Valve
GAS CONTROL VALVE DIAGNOSTICS:
Turn power OFF. Remove and reinsert connector “K” on
Control Board. Attempt to operate unit again. IF 71 Error
Code does NOT display, unit had a loose connection.
1
Visually inspect Gas Control Valve wiring harnesses for
loose or damaged terminals. Gas Control Valve is located
on lower right side of unit.
Continue to diagnostic chart on next page.
2
Gas Control Valve