[How To Check Test Point Gas Pressure]
When press the Maximum Button (SW2) or Minimum Button (SW1), the combustion is fi xed at Maximum or Minimum
and then the LED of remote control displays as follows.
1
__
L
__
Minimum Combustion
1st Step Combustion
4
__
H
__
Maximum Combustion
4th Step Combustion
Note: Make sure that you adjusted the DIP switch setting, if necessary, for the high altitude setting, etc.
Standard Pressure (inch in w.c.)
PHH-32RDV
PHH-25RDV
L.P.
NAT
L.P.
NAT
Minimum Capacity
0.91/11.0
0.71/7.1
0.91/11.0
0.71/7.1
Maximum Capacity
3.64/11.0
3.13/7.1
2.24/11.0
1.97/7.1
Slow Ignition Point
2.76/11.0
2.52/7.1
2.76/11.0
2.52/7.1
PHH-32ROF
PHH-25ROF
L.P.
NAT
L.P.
NAT
Minimum Capacity
0.89/11.0
0.65/7.1
0.89/11.0 0.65/7.1
Maximum Capacity
3.46/11.0
3.11/7.1
2.17/11.0 1.97/7.1
Slow Ignition Point
2.76/11.0
2.68/7.1
2.76/11.0 2.68/7.1
- 128 -
Содержание PH2-20R OFN
Страница 158: ...158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 159: ...159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 160: ...160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS...
Страница 162: ...162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 163: ...163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 164: ...164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF...
Страница 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166...
Страница 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167...
Страница 169: ...169 Schematic Disassembly PHH 32ROF PHH 25ROF...
Страница 170: ...170 matic Disassembly PHH 32ROF PHH 25ROF...