background image

Installation and Homeowners Guide

Underscore Bathroom Heater S300

S300

K-22489T-0

KOHLER CHINA INVESTMENT CO., LTD

NO.158, JIANG CHANG SAN ROAD,

JING'AN DISTRICT, SHANGHAI, PRC

POST CODE: 200436

(

)

158

200436

1369766-T01-E

Содержание K-22489T-0

Страница 1: ...llation and Homeowners Guide Underscore Bathroom Heater S300 S300 K 22489T 0 KOHLER CHINA INVESTMENT CO LTD NO 158 JIANG CHANG SAN ROAD JING AN DISTRICT SHANGHAI PRC POST CODE 200436 158 200436 1369766 T01 E ...

Страница 2: ...iance shall be installed according to the national wiring rules Otherwise it may cause electric shock or fire This product must be used under the power supply with leakage protection switch conforming to CCC the leakage current is below 30mA Otherwise it may cause electric shock and fire When installing the product A power full pole switch with a contact opening distance of not less than 3mm must ...

Страница 3: ...arning Do not install near curtains and other combustible materials Otherwise combustibles may be ignited Warning Warning Warning Warning It is forbidden to place the product directly under the power socket Otherwise it may cause fire It is forbidden to use methods other than those specified in this manual for installation Otherwise the product may fall and cause injury This product must be ground...

Страница 4: ...ctory The exhaust air volume air change noise and other data are the test results of Kohler company which are all central values which are measured under the static pressure of 0 Pa The error of exhaust air volume shall not be less than 90 of the express value The ventilation noise value is A weighted average sound pressure level which is the central value of Kohler company s test results and the ...

Страница 5: ...into the pillar terminal hole and make sure all the cords under the terminal are inserted into the pillar terminal completely Suggest using a power cord which with specification 60227 IEC 53 Model s powercord Specified in GB T 5023 5 and with cross section of 3X1 5mm GB T 5023 5 60227 IEC 53 3X1 5mm 2 2 WIRING INSTRUCTION Bathroom Heater Bathroom Heater Live Wire Live Wire Null Wire Null Wire Eart...

Страница 6: ...Outlet window installation Fix the air exhaust pipe to the outlet window on the wall with the clamp as the preparation of bathroom heater installation Seal the pipe and the outlet window with foaming agent 1 2 Ceiling Air Exhaust Pipe Wall Inside Outside Outlet Window The situation of outlet window on the wall outside The situation of outlet window on the wall inside Outlet Window Outlet Window Ho...

Страница 7: ...that the gap between the product edge and the wall is 300mm or above The power cord to the product shall have enough length for the installation The distance between the product and the air outlet window shall be 1000mm or lower Cut the screw rod M6 to suit the distance between the ceiling and the roof Keels should afford at least 25kg 200mm 200mm 300mm 1000mm M6 25kg Air Exhaust Pipe Wall Lower t...

Страница 8: ...or installation see the figures below 3 Match a keel lock with an L mounting bracket 4 Pre install the 4 matched L mounting brackets on the keel Make sure the installation clearance is appropriate The location of L mounting brackets can be adjusted on the keel before the columnar round screws are tightened 2 3 L 4 4 L L 300mm 300mm integrated ceiling 300mm 300mm 300mm 450mm integrated ceiling 300m...

Страница 9: ...y tighten the 8 BTP4 8 triangular self tapping screws and the columnar screws 5 BTP4 8 L 6 BTP4 8 8 7 Fix the ventilation outlet assembly on the body with one BTP4 8 triangular self tapping screws Then fix air exhaust pipe on the ventilation outlet assembly with a clamp 7 BTP4 8 1 8 BTP4 8 Triangular Self Tapping Screw BTP4 8 8 BTP4 8 Triangular Self Tapping Screw BTP4 8 Decorated Plate Decorated ...

Страница 10: ...S GUIDE A Button Function A Heater Turn on off or switch to the heater mode Fan Turn on off or switch to the fan mode Ventilation Turn on off or switch to the ventilation mode Air Flow Switch the air flow to fixed flow or swing flow defaulted Power Line Wall Controller Wall Controller L L Wall Controller N N Screw 2 ST4 10 Self Tapping Screw ST4 10 Base Wall Controller Back Cover Power Line of Wal...

Страница 11: ...essful after a beeping sound The host of this product and the Wall Controller Assy have been set and paired Each host is packaged with a Wall Controller Assy Do not confuse the host with the wall mounted switch during installation and removal Avoid pairing again B 30 30 3 3 2 C 3 2 TROUBLESHOOTING Problem Diagnosis Solution Bathroom heater does not work Wall controller break down A Power failure B...

Страница 12: ... liquid detergent to clean casing or air louver 3 Never try to put a small screw driver or any other object into the holes of air Louver from outside This might cause damage to the interior parts and electric shock may occur 4 Shut off the all pole switch 5 Wipe the front panel and the panel base with a soft cloth 6 Remove the filter from the louver 7 Use a vacuum cleaner to remove dust and dirt f...

Страница 13: ...experience and common sense use or approach this product close monitoring is necessary Children should not be allowed to use or contact this product Children should not be left alone in the bathroom to play with switches and other devices 7 For children and the elderly who are unable to use a bathroom heater on their own help is needed to set up work patterns that are appropriate for them 8 This p...

Отзывы: