background image

20 

Air Flow Clearance 

A 4-inch clearance from the vent openings on the top of the firebox is required. Framing and/or building material is 

NOT

 permitted in 

this area. Doing so will block the air vents on the fireplace and cause the entire surrounding to overheat. 

Framing Clearance 

Maintain a minimum 

1

/

4

 inches of space between the framing and the face of the fireplace. 

Содержание Clear 130 LS

Страница 1: ...ilt In Models V3 Installation and Operation Manual Built In Models Built In Models Front Facing Traditional Corner RS LS Tunnel Three Side Space Creator Curve Island Wilderness Manufacturer Update Ser...

Страница 2: ...geways of the fireplace must be kept clean Any alteration to the product can cause soot or carbon to form and may result in damage This damage and any other damage that results from not following the...

Страница 3: ...a TV Artwork 26 Access Panel 28 Chase Area Minimum 29 Recessed Ledge Detail 29 Structural Weight Support 30 Step by Step Chase Construction 31 Finishing 32 Flush Installation 32 Recessed Installation...

Страница 4: ...place Certified to US Standard CLASS 2901 04 DOMESTIC HEATERS GAS Vented Fireplace The fireplaces are permitted for indoor use only Indoor is defined as a conditioned space The fireplaces are not appr...

Страница 5: ...F RS LS TS TN Island 130 100 Single US ANSI Z21 88 2016 Canada CSA 2 33 2016 Natural Gas or Propane 5 x8 Co axial Direct Vent 44 51 60 Wilderness 44 F RS LS TS Wilderness 51 F RS LS TS Wilderness 60...

Страница 6: ...rating label with the fireplace in an area easily accessible by the owner typically near the access panel if available You must instruct the owner before handing over the fireplace where this label c...

Страница 7: ...ming with 5 8 Type X Drywall Platform Gas and electric Access panel if applicable Heat release Air intake if applicable Clear a path free of any possible obstruction to carry in the fireplace Uncrate...

Страница 8: ...s and clean the inside of the fireplace Install the Interior Design Media if desired on the burner as specified in Interior Design Media section Confirm the fireplace is operating properly Check remot...

Страница 9: ...turn and perform the final inspection which includes Cleaning the glass with a ceramic glass cleaner otherwise the white residue will remain Checking the interior media setup Checking for gas leaks Ad...

Страница 10: ...fireplace viewing area must always be non combustible framing Maintain min 1 4 clearance from front face of fireplace and front metal off set to the framing Maintain min 4 space between air vents at t...

Страница 11: ...raming Dimensions The following diagrams are for illustrative purposes only There are multiple approved installation scenarios A flush application is not the only permitted application The fireplace m...

Страница 12: ...ible 45 1 8 37 3 4 18 15 3 8 Non Combustible 29 7 8 N A 75x65 F Combustible 53 3 8 38 3 8 18 15 1 8 Non Combustible 38 3 8 N A 60x80 F Combustible 57 29 3 8 18 1 8 14 5 8 Non Combustible 42 1 2 N A 11...

Страница 13: ...n Combustible 41 3 8 N A 75 RS LS Combustible 46 3 4 35 1 4 20 1 8 13 1 4 Non Combustible 33 1 2 N A 110 RS LS Wilderness 44 RS LS Combustible 43 5 8 50 3 4 20 5 8 12 1 2 Non Combustible 31 1 8 N A 11...

Страница 14: ...s 14 3 8 Non Combustible 41 1 4 N A 75x65 TN Combustible 53 3 8 38 3 8 19 1 8 15 1 8 Non Combustible 38 3 8 N A 60x80 TN Combustible 57 29 3 8 19 1 8 14 5 8 Non Combustible 42 3 8 N A 110 TN Combustib...

Страница 15: ...stop dimensions 14 1 8 Non Combustible 41 3 8 N A 75 TS Combustible 38 3 4 33 5 8 20 1 8 13 1 4 Non Combustible 33 1 2 N A 110 TS Wilderness 44 TS Combustible 43 5 8 49 20 5 8 12 1 2 Non Combustible 3...

Страница 16: ...imum 4 of clearance to any material achieve sufficient airflow Failure to do so could result in improper fireplace operation property damage or physical injury Review General Clearances section prior...

Страница 17: ...additional layer of 5 8 Type X Drywall is required to line the inside of the chase as well Platform The fireplace must be installed on a flat solid continuous surface Surface can be wood concrete meta...

Страница 18: ...st be minimum 36 inches from fireplace viewing area Materials including combustible flooring and combustible finish material are permitted below and around the viewing area clearance zone IMPORTANT NO...

Страница 19: ...g on the model to any material Firebox Clearance Per Model Front Traditional Tunnel Corner Left Side Corner Ride Side Space Creator Three Side Clearance to Ceiling Maintain a 12 inch clearance from th...

Страница 20: ...rebox is required Framing and or building material is NOT permitted in this area Doing so will block the air vents on the fireplace and cause the entire surrounding to overheat Framing Clearance Maint...

Страница 21: ...does not apply to a wall that is constructed in front of the viewing area For materials that will be in front of a main or side viewing area please refer to the Viewing Area Clearances section NOTE Th...

Страница 22: ...0 Minimum 250 sq in of free air space Minimum 325 sq in of free air space Includes Built In Curve Island fireplaces Heat release requirements do not apply to Stand alone Curve stand alone Island firep...

Страница 23: ...release is oriented vertically Entire heat release is on one side of the fireplace chase Split Front Vertical Heat Release Full Vertical Heat Release on One Side Sprinkler Clearance to Heat Release In...

Страница 24: ...sq in of free air space 250 Minimum 250 sq in of free air space Includes Built In Curve Island fireplaces Stand alone Curve Island fireplaces have an air intake already built into the base The air in...

Страница 25: ...25 Air Intake for a Platform NOTE Please refer to the Platform section for details on platform construction...

Страница 26: ...d prevent heat damage Mount the TV or artwork a minimum of 12 inches above the top of the fireplace viewing area TV wires must be routed through framing and cannot pass through the fireplace chase The...

Страница 27: ...ecess is 3 3 4 inches A deeper recess will interfere with required clearances to venting Maximum possible recess increases at 12 inches above the viewing area when venting is offset as shown in diagra...

Страница 28: ...lation fireplace dealers installers should work with the owner builder project architects and or interior designers to determine the best size and location of their access panel If an access panel can...

Страница 29: ...he top of a fireplace that is less than 24 inches 48 inches for Traditional series from the top of the fireplace viewing area must maintain a minimum of 12 inches from the top of the viewing area to t...

Страница 30: ...face Consult with the project structural engineer and refer to your local building codes for proper wall support The following drawing shows a recommended approach to this type of installation Please...

Страница 31: ...ove the gas valve and receiver unit to the designated access panel location If the fireplace will not have an access panel keep gas valve and receiver unit directly underneath the fireplace Skip this...

Страница 32: ...viewing area This area must be unobstructed to allow the heat barrier and inside glass panel to be removable MANUFACTURED STONE A minimum 2 inch recess is suggested Consult stone manufacturer for cle...

Страница 33: ...33 Recessed Installation Diagram applies to both combustible and non combustible finish material The finish must maintain at least a 1 8 clearance to the fireplace...

Страница 34: ...axial direct vent pipe 5 inch interior 8 inch exterior Olympia Ventis DuraVent Direct Vent Pro ICC EXCELDirect BDM Pro Form Direct Vent System Selkirk Direct Temp System Enervex Power Vent see note b...

Страница 35: ...Island and Curve fireplaces See Offset Maximum Exception below Offset Maximum Up to 180 of offset elbows can be used in the vent configuration If the vent configuration exceeds this maximum consider a...

Страница 36: ...Traditional Series 200 250 V minimum 3 feet V minimum 3 feet V minimum 3 feet V minimum 6 feet Vertical V Max Horizontal H Vertical V Max Horizontal H Vertical V Max Horizontal H Vertical V Max Horiz...

Страница 37: ...6 ft 3 ft 10 ft 18 ft 10 ft 18 ft 10 ft 15 ft 10 ft 12 ft 13 ft 18 ft 13 ft 15 ft 13 ft 12 ft 13 ft 12 ft 16 ft 18 ft 16 ft 15 ft 16 ft 12 ft 16 ft 12 ft 19 ft 15 ft 19 ft 12 ft 19 ft 12 ft 19 ft 12 f...

Страница 38: ...feet so the H length is 27 feet Per the table the restrictor plate is 0 No restrictor is required SCENARIO C The vent configuration has one 90 offset The first 90 offset is not taken into calculation...

Страница 39: ...Represents the recommended restrictor by width Restrictor Sizes 20mm 0 79 30mm 1 18 40mm 1 57 50mm 1 97 60mm 2 36 80mm 3 15 Recommended Restrictor Series 40 Total Vertical Vent Rise 27 1 97 1 57 1 57...

Страница 40: ...18 0 x x x x 21 1 97 1 97 1 97 1 57 1 18 1 18 1 18 0 0 x x x 18 1 97 1 97 1 97 1 57 1 18 1 18 1 18 0 0 0 x x 15 1 97 1 97 1 57 1 57 1 18 1 18 1 18 x 0 0 0 x 12 1 57 1 57 1 57 1 57 1 18 1 18 1 18 x 0...

Страница 41: ...8 0 0 0 x x x x 6 1 97 1 57 1 57 1 18 0 0 0 x x x x x 3 x x x x x x x x x x x x 0 3 6 9 12 15 18 21 24 27 30 33 Horizontal Vent Run Recommended Restrictor Series 250 Total Vertical Vent Rise 27 x x x...

Страница 42: ...3 feet minimum between termination caps 2 All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap 3 All gravity air intakes within 3 feet...

Страница 43: ...within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap 3 All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the terminatio...

Страница 44: ...44 Vertical Termination Clearance Diagram NOTE This chart does not apply to a chimney shroud application See the Chimney Shroud section on the next page for more information...

Страница 45: ...ding above and below the cap Sides Open Keep a minimum 6 inch clearance around the diameter of the cap s side edge and a minimum 10 inch clearance above the top of the cap For openings in the shroud m...

Страница 46: ...th Co linear flexible aluminum venting must be professionally inspected periodically for corrosion and damage and replaced when necessary If the installation does not allow for future inspection or re...

Страница 47: ...se 10 feet see diagram below Maximum Vertical Rise 40 feet see diagram below Offsets Two 45 offsets may be used directly on the fireplace with up to a 6 foot section between them The minimum vertical...

Страница 48: ...55 000 650 Front 800 Rear Standard Double Propane 11 0 13 0 10 0 17 265 53 238 160 Front 220 Rear 110 120 130 100 Single Natural Gas 5 0 10 0 5 6 22 798 37 167 1200 Propane 11 0 13 0 10 0 25 113 35 3...

Страница 49: ...off valve and a 12 gas flex connector are provided with every fireplace The location of the gas shut off valve is dependent on local codes and requirements Check with your authority having jurisdicti...

Страница 50: ...Electrode Target Type D36 Orifice NG G121 Main Burner Gas Fitting G02 Mertik Gas Valve G25 Burner Gas Tube G301 Symax Receiver G19 Pilot Gas Tube G202 XRGB Symax Wi Fi Box G34 Spark Plug Connector G2...

Страница 51: ...ouble glass heat barrier power vent or a heat control system may not be used with batteries Pairing the Remote and Receiver To set up the remote control device to operate the fireplace follow the foll...

Страница 52: ...52 Wiring Diagrams The following diagrams show the electrical wiring required for different feature combinations Wiring Diagram Screen Fireplace...

Страница 53: ...53 Wiring Diagram Screen Fireplace with Interior Lighting...

Страница 54: ...54 Wiring Diagram Screen Fireplace with Interior Lighting and Ortal Power Vent...

Страница 55: ...55 Wiring Diagram Double Glass Fireplace...

Страница 56: ...56 Wiring Diagram Double Glass Fireplace with Interior Lighting...

Страница 57: ...57 Wiring Diagram Double Glass Fireplace with Interior Lighting and Ortal Power Vent...

Страница 58: ...58 Carbon Monoxide Detector Wiring Diagrams CO Kit Wiring Diagram Screen Fireplace...

Страница 59: ...59 CO Kit Wiring Diagram Double Glass Fireplace...

Страница 60: ...ss logs and embers that can provided with the fireplace This section provides guidelines for safe placement of media It is crucial that the placement guidelines outlined below are followed as a large...

Страница 61: ...l injury Do not use the hood to support media This could cause overheating of the thermocouple Keep the media away from the edges and the glass Do not overfill the media tray Keep 20 of the tray open...

Страница 62: ...w ports as possible If a log is placed over a port block the port with a coin to keep the flame from creating soot on the media or to manipulate the look of the flame Block as few ports as possible an...

Страница 63: ...will be affected when handset is in use Operating Instructions Instructions for operating the 10 Button Handset are shown below For more in depth instructions please refer to the Homeowner s Fireplac...

Страница 64: ...se flame height or to set fireplace to pilot flame only press and hold the button Wall Switch Operating Instructions Turning the Fireplace On Off ON Press and hold the ON OFF button until two short be...

Страница 65: ...ated within 26 feet of the receiver NOTES For detailed App setup and operating instructions refer to the Homeowners Operation and Maintenance Guide www myfireapp com The myFire Wi Fi box is required f...

Страница 66: ...e removed ONLY by an authorized Ortal dealer service technician The Ortal dealer service technician should ONLY remove the glass with the suction cup supplied by the manufacturer Lower the glass to re...

Страница 67: ...Ortal 2021 Version 3 March 2021 SKU KPMANUALUS3 0 Ortal USA 8421 Canoga Ave Canoga Park CA 91304 T 818 238 7000 F 818 678 0541 info ortalheat com www ortalheat com...

Отзывы: