Power removal function
82
3 DC po
z
ETO reset ineffective period
The motor cannot be excited even if the ETO-CLR input is turned ON until the time set in the “ETO reset ineffective
period” parameter is elapsed.
Related parameter
Parameter ID
Name
Description
Initial
value
Dec
Hex
408
0198h
ETO reset ineffective
period
Sets a time to disable the ETO-CLR input if the motor is
excited by the ETO-CLR input after both the HWTO1 and
HWTO2 inputs are turned ON. The motor cannot be
excited until the time set in this parameter is exceeded
even if the ETO-CLR input is turned ON.
[Setting range]
0 to 100 ms
0
When the ETO-CLR input is turned ON before the time set in the “ETO reset ineffective period”
parameter is elapsed (when the motor is excited at the ON edge of the input)
15 ms or less
ETO reset ineffective period
The motor cannot be excited even if
the ETO-CLR input is turned ON within
the ETO reset ineffective period
READY output, PLS-RDY output
OFF
ON
ETO-CLR input
OFF
ON
Driver status
Power removal status
HWTO1 input, HWTO2 input
OFF
ON
Non-excitation
Excitation
Motor excitation
When the ETO-CLR input is turned ON after the time set in the “ETO reset ineffective period” parameter
is elapsed (when the motor is excited at the ON edge of the input)
15 ms or less
200 ms or less
ETO reset ineffective period
The motor can be excited if the
ETO-CLR input is turned ON after the
ETO reset ineffective period is elapsed
READY output, PLS-RDY output
OFF
ON
ETO-CLR input
OFF
ON
Driver status
Power removal status
HWTO1 input, HWTO2 input
OFF
ON
250 ms or less
Non-excitation
Excitation
Motor excitation