Parameter R/W commands
149
5 P
ar
8-19
User output setting parameters
Parameter ID
Name
Setting range
Initial value
Update
Dec
Hex
2400
0960h
User output (USR-OUT0) source A function
Output signals list
_
128: CONST-OFF
C
2401
0961h
User output (USR-OUT1) source A function
2402
0962h
User output (USR-OUT0) source A inverting mode
0: Non invert
1: Invert
0
2403
0963h
User output (USR-OUT1) source A inverting mode
2404
0964h
User output (USR-OUT0) source B function
Output signals list
_
128: CONST-OFF
2405
0965h
User output (USR-OUT1) source B function
2406
0966h
User output (USR-OUT0) source B inverting mode
0: Non invert
1: Invert
0
2407
0967h
User output (USR-OUT1) source B inverting mode
2408
0968h
User output (USR-OUT0) logical operation
0: AND
1: OR
1
2409
0969h
User output (USR-OUT1) logical operation
8-20
Driver mode setting parameters
Parameter ID
Name
Setting range
Initial value
Update
Dec
Hex
496
01F0h
PULSE-I/F mode selection
−1: Disable
1: 2 pulse input mode
2: 1 pulse input mode
3: Phase-shifted pulses input mode (×1)
4: Phase-shifted pulses input mode (×2)
5: Phase-shifted pulses input mode (×4)
1
D
498
01F2h
USB-ID enable
0: Disable
1: Enable
1
499
01F3h
USB-ID
0 to 999,999,999
0
2555
09FBh
USB-PID
0 to 31
0
8-21
Assignable monitor setting parameters
Parameter ID
Name
Description
Setting range
Initial value
Update
Dec
Hex
25600
6400h
Assignable monitor
address 0
These are used to
set the parameter ID
to show on the
assignable monitor.
Set from items of “3
Monitor commands”
on p.124 .
124: Driver temperature
A
25601
6401h
Assignable monitor
address 1
125: Motor temperature
25602
6402h
Assignable monitor
address 2
109: Cumulative load
monitor
25603
6403h
Assignable monitor
address 3
127: Tripmeter
Содержание aSTEP AZ Series