Alarms
162
6 T
Related parameters
Parameter ID
Name
Description
Initial value
Dec
Hex
384
0180h
Overload alarm
Sets the condition in which the overload alarm is
generated.
[Setting range]
1 to 300 (1=0.1 s)
50
385
0181h
Excessive position
deviation alarm
Sets the condition in which the excessive position
deviation alarm is generated.
[Setting range]
1 to 30,000 (1=0.01 rev)
300
24968
6188h
Network bus error alarm
Sets the function of the network bus error alarm.
[Setting range]
0: Disable
1: Enable
1
About causes of the motor combination error (alarm code 45h)
An alarm of the motor combination error is generated in the following conditions.
•
When the motor for a DC power supply was connected to the AC power input driver.
•
When the motor for an AC power supply was connected to the DC power input driver.
•
When the motor of frame size 20 mm (0.79 in.) or 28 mm (1.10 in.) was connected to the DC power input driver and
48 VDC was applied.