Specifications
175
7 R
ef
2
Specifications
2-1
General specifications
AC power input driver
Degree of protection
IP10
Operating
environment
Ambient
temperature
0 to +55 °C (+32 to +131 °F) * (non-freezing)
Humidity
85 % or less (non-condensing)
Altitude
Up to 1,000 m (3,300 ft.) above sea level
Surrounding
atmosphere
No corrosive gas, dust, water, or oil.
Storage
environment
Shipping
environment
Ambient
temperature
−25 to +70 °C (−13 to +158 °F) (non-freezing)
Humidity
85 % or less (non-condensing)
Altitude
Up to 3,000 m (10,000 ft.) above sea level
Surrounding
atmosphere
No corrosive gas, dust, water, or oil.
Insulation resistance
100 MΩ or more when 500 VDC megger is applied between the following places:
· Protective Earth Terminal - Main power supply input terminal
· Encoder connector - Main power supply input terminal
· I/O signal connector - Main power supply input terminal
Dielectric strength
Sufficient to withstand the specified voltage applied between the following places
for 1 minute:
· Protective Earth Terminal - Main power supply input terminal 1.5 kVAC 50/60 Hz
· Encoder connector - Main power supply input terminal 1.8 kVAC 50/60 Hz
· I/O signal connector - Main power supply input terminal 1.8 kVAC 50/60 Hz
* When installing a driver on a heat sink [material: aluminum, 200×200×2 mm (7.87×7.87×0.08 in.) or equivalent].
DC power input driver
Degree of protection
IP10
Operating
environment
Ambient
temperature
0 to +50 °C (+32 to +122 °F) (non-freezing)
Humidity
85 % or less (non-condensing)
Altitude
Up to 1,000 m (3,300 ft.) above sea level
Surrounding
atmosphere
No corrosive gas, dust, water, or oil.
Storage
environment
Shipping
environment
Ambient
temperature
−25 to +70 °C (−13 to +158 °F) (non-freezing)
Humidity
85 % or less (non-condensing)
Altitude
Up to 3,000 m (10,000 ft.) above sea level
Surrounding
atmosphere
No corrosive gas, dust, water, or oil.
Insulation resistance
100 MΩ or more when 500 VDC megger is applied between the following places:
· Protective Earth Terminal - Power supply input terminal *
* The main power supply input terminals and the control power supply input terminals are not electrically insulated.
Check using either of terminals.