Connection
67
3 DC po
4-4
Grounding the driver
Be sure to ground the driver.
Using the CN4 connector (6 pins), ground the driver. Refer to p.66 for the wiring method.
Note that the applicable wire size varies between lead wires for a main power supply and Protective Earth.
Do not share the grounding wire with a welder or any other power equipment.
Connect to CN4
+24 VDC
+48 VDC
GND
Grounding
4-5
Connecting the PROFINET communication cable (CN5, CN6)
Connect the PROFINET communication cable to the PROFINET communication connector (CN5, CN6).
Pin assignment
Signal name
Description
TXP
Transmitted data+
TXN
Transmitted data−
RXP
Received data+
N.C.
−
N.C.
−
RXN
Received data−
N.C.
−
N.C.
−
TXP
TXN
RXP
N.C.
N.C.
RXN
N.C.
N.C.
4-6
Connecting the USB cable
Using a USB cable of the following specification, connect a PC in which the
MEXE02
has been installed to the USB
communication connector.
Specification USB2.0 (full speed)
Cable
Length: 3 m (9.8 ft.) or less
Shape: A to mini B
•
Connect the driver and PC directly using the USB cable.
•
In large electrically noisy environments, use the USB cable with a ferrite core or install a ferrite core
to the USB cable.