Information
165
6 T
3
Information
The driver is equipped with a function to generate information output before an alarm is generated.
This function can be utilized for periodic maintenance of equipment by setting a suitable value in the parameter of
each information.
For example, utilizing the “Motor temperature information” parameter can prevent equipment malfunction or
production stoppage due to motor overheat. In addition, the “Tripmeter information” parameter can be utilized as a
reference to do maintenances every time a certain travel distance is reached.
Status when information is generated
z
Information bit output
If information is generated, a bit output (INFO-
**
output) of the corresponding information is turned ON.
A desired output signal can be assigned to the INFO-USRIO output among bit outputs and used. If the assigned
output signal is turned ON, the INFO-USRIO output is also turned ON. (Details of bit output
_
z
INFO output
If information is generated, the INFO output is turned ON.
z
LED indicator
If information is generated, the PWR/ALM LED will simultaneously blink in red and green twice. (Red and green colors
may overlap and it may be visible to orange.)
z
Motor operation
The motor continues to operate during information unlike in the case of an alarm.
z
Parameter
Each information has a corresponding “INFO action” parameter. If the parameter is set to “0: No Info reflect,” only the
bit output of information is turned ON, and the INFO output and LED are not changed.
Related parameters
Parameter ID
Name
Description
Initial value
Dec
Hex
416
01A0h
Driver temperature information
(INFO-DRVTMP)
Sets the generation condition of the driver
temperature information (INFO-DRVTMP).
[Setting range]
40 to 85 °C
85
417
01A1h
Overload time information
(INFO-OLTIME)
Sets the generation condition of the overload time
information (INFO-OLTIME).
[Setting range]
1 to 300 (1=0.1 s)
50
418
01A2h
Overspeed information (INFO-SPD)
Sets the generation condition of the overspeed
information (INFO-SPD).
[Setting range]
0: Disable
1 to 12,000 r/min
0
421
01A5h
Position deviation information
(INFO-POSERR)
Sets the generation condition of the position
deviation information (INFO-POSERR).
[Setting range]
1 to 30,000 (1=0.01 rev)
300
424
01A8h
Motor temperature information
(INFO-MTRTMP)
Sets the generation condition of the motor
temperature information (INFO-MTRTMP).
[Setting range]
40 to 120 °C
85