background image

HP-5123

Brushless Motor

BX

 

Series

  

Driver Edition

OPERATING MANUAL

    

    

Thank you for purchasing an Oriental Motor product.
This Operating Manual describes product handling procedures and safety precautions.

 

Please read it thoroughly to ensure safe operation.

 

Always keep the manual where it is readily available.

Table of contents

1 Introduction ..........................................................2
2  Safety precautions ..............................................3
3  Precautions for use .............................................5
4 Preparation ............................................................8

4.1  Checking the product .............................................. 8
4.2  How to identify the product model.................... 8
4.3  Information about nameplate .............................. 8
4.4  Products possible to combine .............................. 8
4.5  Names and functions of parts .............................. 9

5 Installation .......................................................... 10

5.1  Installation location ................................................10
5.2  Installing the driver ................................................10
5.3  Installing the external potentiometer  

(sold separately) ......................................................12

5.4  Installing the regeneration resistor  

(sold separately) ......................................................12

6 Connection ......................................................... 14

6.1  Connection example ..............................................14
6.2  Connecting the power supply (CN1)................15
6.3  Circuit breaker ..........................................................15
6.4 Grounding .................................................................15
6.5  Connecting the motor (CN2, CN3, CN4) .........16
6.6  Selecting a power supply for input signals ....16
6.7  Connecting the I/O signals (CN5, CN7)............16
6.8  Connecting analog external setting  

devices ........................................................................17

6.9  Connecting the data setter (CN6) .....................17
6.10  Connecting the regeneration resistor  

(sold separately) ......................................................18

7 Operation ............................................................ 19

7.1  Operation by input signals ..................................19
7.2  Test operation (JOG operation) ..........................21

8  Operation panel ................................................ 22

8.1  Names of parts for operation panel .................22
8.2  Main screen transitions .........................................22

9  Maintenance and inspection ....................... 23

9.1 Inspection ..................................................................23
9.2 Warranty .....................................................................23
9.3 Disposal ......................................................................23

10  Protective function .......................................... 24

10.1  Alarm list.....................................................................24
10.2  Warning list................................................................25

11 Specifications ..................................................... 26
12  Regulations and standards ........................... 27

12.1  UL Standards, CSA Standards .............................27
12.2  CE Marking ................................................................27
12.3  Republic of Korea, Radio Waves Act .................27
12.4  RoHS Directive ..........................................................27

Содержание BX2 Driver Edition Series

Страница 1: ...ration resistor sold separately 12 6 Connection 14 6 1 Connection example 14 6 2 Connecting the power supply CN1 15 6 3 Circuit breaker 15 6 4 Grounding 15 6 5 Connecting the motor CN2 CN3 CN4 16 6 6...

Страница 2: ...this warning Operating manuals for the product Operating manuals for this product are listed below For operating manuals not included with the product contact your nearest Oriental Motor sales office...

Страница 3: ...sing injury or damage to equipment Do not touch the motor or driver when conducting the insulation resistance measurement or dielectric strength test Accidental contact may result in electric shock Do...

Страница 4: ...sulting in injury or damage to equipment For the power supply of I O signals use a DC power supply with reinforced insulation on its primary and secondary sides Failure to do so may result in electric...

Страница 5: ...onnector part Fix using two banding bands or a wide clamp Fixing at one place on each side Fixing at two places on each side Connector Connector Banding band etc Banding band etc When installing the m...

Страница 6: ...n or off the power supply via a solid state relay SSR may damage the motor and driver z z When the motor is used in vertical drive gravitational operation or in drive with a large inertia use a regene...

Страница 7: ...7 Precautions for use...

Страница 8: ...W 400 400 W Power supply voltage A Single phase 100 120 VAC C Single phase 200 240 VAC Three phase 200 240 VAC Identification code 4 3 Information about nameplate The following nameplate is an example...

Страница 9: ...ned off the LED is turned off once the residual voltage in the driver drops to a safe level Motor connector CN2 MOTOR Connects the motor power connector of the connection cable Regeneration resistor t...

Страница 10: ...vection and conduction through the enclosure Install the driver in a state where clearances of at least 25 mm 0 98 in in the horizontal and vertical directions between the driver and enclosure or othe...

Страница 11: ...rately and mount it to a 35 mm 1 38 in wide DIN rail Refer to MADP02 handling guideline for installation method z z Installation using driver mounting brackets Use the included mounting screws to secu...

Страница 12: ...Lead wire Terminal Heat shrinkable tube Solder Pass the lead wire through the terminal hole and give it two or three turns Dial Variable resistor 5 4 Installing the regeneration resistor sold separate...

Страница 13: ...13 Installation...

Страница 14: ...1 Regeneration resistor Connect to CN1 Note Be sure to use the dedicated connection cable sold separately to connect the motor Regardless of whether an electromagnetic brake is equipped or not always...

Страница 15: ...nal L1 and the neutral side to terminal L2 If either of them is connected to terminal L3 the motor does not rotate Connect the R S and T phase lines to L1 L2 and L3 terminals respectively 6 3 Circuit...

Страница 16: ...The built in power supply cannot be used in the case of source logic Do not turn the switch ON 6 7 Connecting the I O signals CN5 CN7 Connect the input signals to CN5 and the analog external input si...

Страница 17: ...tting for the operating speed or torque limit can be performed For the external DC voltage use a DC power supply 0 to 10 VDC with reinforced insulation on its primary and secondary sides The input imp...

Страница 18: ...CN5 and IN COM1 Regeneration resistor AWG22 TH input IN COM1 150 C 302 F N C Connect to CN1 AWG18 R RG2 terminal RG1 terminal Note The TH input is not assigned to CN5 at the time of shipment When usi...

Страница 19: ...or in the clockwise direction 3 IN1 RVS This signal is used to rotate the motor in the counterclockwise direction 8 IN6 STOP This signal is used to stop the motor instantaneously 11 IN COM1 Input sign...

Страница 20: ...ince it rotates lightly Doing so may damage the product z z Setting with analog external setting devices Using PAVR 20KZ sold separately When using the PAVR 20KZ turn the M0 input ON Turning the PAVR...

Страница 21: ...key once again The display changes to 0 6 Operate the motor in JOG operation by pressing the key or key The operating speed is displayed during JOG operation The motor rotates in the clockwise directi...

Страница 22: ...arameter refer to the USER MANUAL When a power supply is turned on the speed of the monitor mode is displayed initial setting Use the monitor mode when operating the motor Monitor mode Speed Load fact...

Страница 23: ...r dielectric strength test on an encoder itself Doing so may damage the encoder Inspection item Check if any of the mounting screws of the motor and gearhead is loose Check if the bearing part ball be...

Страница 24: ...me Connect the regeneration resistor Undervoltage The power supply voltage dropped below approximately 60 of the rated voltage Check the voltage of the main power supply Check the wiring of the power...

Страница 25: ...ation data of different directions was linked in linked motion operation Five operation data or more was linked Positioning operation was performed at the operating speed of 0 r min Check the operatio...

Страница 26: ...rmissible voltage range 15 to 10 Rated frequency 50 60 Hz Permissible frequency range 5 Rated input current Single phase 3 7 A Single phase 2 3 A Three phase 1 1 A Single phase 4 7 A Single phase 2 8...

Страница 27: ...tegory Pollution degree 2 Protection against electric shock Class EMC Directive This product has received EMC compliance under the conditions specified in Example of installation and wiring on the USE...

Страница 28: ...ducts mentioned in this manual are recommended products and references to their names shall not be construed as any form of performance guarantee Oriental Motor is not liable whatsoever for the perfor...

Отзывы: