Connection
CN7 pin assignments
Pin No.
Signal name
Function
∗
1
VH
Analog external setting input
1
2
3
8
9
10
12
11
4
5
6
7
Manufacturer: PHOENIX CONTACT GmbH & Co. KG
Model: FK-MC0,5/12-ST-2,5
2
VM
3
VL
4
OUT0+
Output terminal 0+ [ALM]
5
OUT0−
Output terminal 0− [ALM]
6
OUT1+
Output terminal 1+ [MOVE]
7
OUT1−
Output terminal 1− [MOVE]
8
OUT2+
Output terminal 2+ [WNG]
9
OUT2−
Output terminal 2− [WNG]
10
ASG
Phase A output
11
BSG
Phase B output
12
OUT-COM
Common for ASG/BSG
∗
The signal in brackets [ ] is a function that is assigned at the time of shipment (speed control mode).
6.8 Connecting analog external setting devices
If the
PAVR-20KZ
(sold separately) or external DC voltage is connected to CN7, the analog setting for the operating
speed or torque limit can be performed.
For the external DC voltage, use a DC power supply (0 to 10 VDC) with reinforced insulation on its primary and
secondary sides.
The input impedance between the VM input and VL input is approximately 41.8 k
Ω
.
z
Connecting
PAVR-20KZ
z
Connecting external DC voltage
Pin No.2 VM input
Pin No.1 VH input
CN7
3
PAVR-20KZ
(sold separately)
2
1
Pun No.3 VL input
Pin No.2 VM input
CN7
Pin No.3 VL input
0 to 10 VDC
1 mA or more
External DC power
supply
Note
Be sure to use the external DC voltage at 10 V or lower. When connecting the external DC power supply, make sure the
polarities are correct. If the polarities are reversed, the driver may be damaged.
6.9 Connecting the data setter (CN6)
Connect the cable of the
OPX-2A
or the communication cable for
support software to CN6.
OPX-2A
cable or communication
cable for support software