4.5  Names and functions of parts

This section explains the name and function for each part of the driver.

I/O signals connector (CN7)

Deceleration time potentiometer (DEC)

Acceleration time potentiometer (ACC)

Input signals connector (CN5)

Data setter connector (CN6)

Function setting switches (SW1)

Display

Operation keys

Internal potentiometer (SPEED)

Encoder connector (CN4)

Electromagnetic brake connector (CN3)

CHARGE LED (Red)

Motor connector (CN2)

Protective Earth Terminals

Regeneration resistor terminals (CN1)

Main power supply input terminals (CN1)

Operation panel

Name

Sign

Description

Operation panel

Display: This display shows the monitor items, setting screen, alarms, etc. (Refer to p.22) 

MODE 

 

∨ 

SET

Operation keys: These keys are used to switch the function mode or change parameters. 
(Refer to p.22)

Internal potentiometer (SPEED)

SPEED

This potentiometer is used to set the operating speed of the motor.

Acceleration time potentiometer (ACC)

ACC

This potentiometer is used to set the acceleration time when the motor is started.

Deceleration time potentiometer (DEC)

DEC

This potentiometer is used to set the deceleration time when the motor is stopped.

Encoder connector (CN4)

SENSOR Connects the encoder connector of the connection cable.

Electromagnetic brake connector (CN3)

MB

Connects the electromagnetic brake connector of the connection cable.

CHARGE LED (Red)

CHARGE

This LED is lit while the main power supply is turned on. After the main power was turned 
off, the LED is turned off once the residual voltage in the driver drops to a safe level.

Motor connector (CN2)

MOTOR Connects the motor power connector of the connection cable.

Regeneration resistor terminals (CN1)

RG1, RG2 Connects the regeneration resistor 

EPRC-400P

 (sold separately) or 

RGB100

 (sold separately).

Main power supply input terminals 
(CN1)

Connects the main power supply.

L, N, NC

 

Single-phase 100-120 VAC: Connects a single-phase 100-120 VAC power supply to L and N. 
NC is not used.

L1, L2, L3

 

Single-phase 200-240 VAC: Connects a single-phase 200-240 VAC power supply to L1 and 
L2. L3 is not used.

 

Three-phase 200-240 VAC: Connects a three-phase 200-240 VAC power supply to L1, L2, L3.

Input signals connector (CN5)

I/O

Connects the input signals.

Data setter connector (CN6)

Connects a PC in which the support software 

MEXE02

 has been installed or the data setter 

OPX-2A

 (sold separately).

Function setting switches (SW1)

SW1

 

SW1-1: This is used to switch between the speed control mode and position control 
mode. [Factory setting: OFF]

 

SW1-2: This is used to set the 

BX

-compatible mode. [Factory setting: OFF]

 

SW1-3: Not used. Keep this switch in the OFF position.

 

SW1-4: This switch is used to select the power supply for input signals (use the built-in 
power supply or external power supply). [Factory setting: OFF] (Refer to p.19)

I/O signals connector (CN7)

I/O

 

Connects the external potentiometer 

PAVR-20KZ

 (sold separately) or external DC power 

supply.

 

Connects the output signals.

Protective Earth Terminals 

Ground using a grounding wire of AWG 18 to 14 (0.75 to 2.0 mm

2

).

Mounting holes (two places at the rear)

These mounting holes are used to install the driver with screws (M4).

Содержание BX2 Driver Edition Series

Страница 1: ...ration resistor sold separately 12 6 Connection 14 6 1 Connection example 14 6 2 Connecting the power supply CN1 15 6 3 Circuit breaker 15 6 4 Grounding 15 6 5 Connecting the motor CN2 CN3 CN4 16 6 6...

Страница 2: ...this warning Operating manuals for the product Operating manuals for this product are listed below For operating manuals not included with the product contact your nearest Oriental Motor sales office...

Страница 3: ...sing injury or damage to equipment Do not touch the motor or driver when conducting the insulation resistance measurement or dielectric strength test Accidental contact may result in electric shock Do...

Страница 4: ...sulting in injury or damage to equipment For the power supply of I O signals use a DC power supply with reinforced insulation on its primary and secondary sides Failure to do so may result in electric...

Страница 5: ...onnector part Fix using two banding bands or a wide clamp Fixing at one place on each side Fixing at two places on each side Connector Connector Banding band etc Banding band etc When installing the m...

Страница 6: ...n or off the power supply via a solid state relay SSR may damage the motor and driver z z When the motor is used in vertical drive gravitational operation or in drive with a large inertia use a regene...

Страница 7: ...7 Precautions for use...

Страница 8: ...W 400 400 W Power supply voltage A Single phase 100 120 VAC C Single phase 200 240 VAC Three phase 200 240 VAC Identification code 4 3 Information about nameplate The following nameplate is an example...

Страница 9: ...ned off the LED is turned off once the residual voltage in the driver drops to a safe level Motor connector CN2 MOTOR Connects the motor power connector of the connection cable Regeneration resistor t...

Страница 10: ...vection and conduction through the enclosure Install the driver in a state where clearances of at least 25 mm 0 98 in in the horizontal and vertical directions between the driver and enclosure or othe...

Страница 11: ...rately and mount it to a 35 mm 1 38 in wide DIN rail Refer to MADP02 handling guideline for installation method z z Installation using driver mounting brackets Use the included mounting screws to secu...

Страница 12: ...Lead wire Terminal Heat shrinkable tube Solder Pass the lead wire through the terminal hole and give it two or three turns Dial Variable resistor 5 4 Installing the regeneration resistor sold separate...

Страница 13: ...13 Installation...

Страница 14: ...1 Regeneration resistor Connect to CN1 Note Be sure to use the dedicated connection cable sold separately to connect the motor Regardless of whether an electromagnetic brake is equipped or not always...

Страница 15: ...nal L1 and the neutral side to terminal L2 If either of them is connected to terminal L3 the motor does not rotate Connect the R S and T phase lines to L1 L2 and L3 terminals respectively 6 3 Circuit...

Страница 16: ...The built in power supply cannot be used in the case of source logic Do not turn the switch ON 6 7 Connecting the I O signals CN5 CN7 Connect the input signals to CN5 and the analog external input si...

Страница 17: ...tting for the operating speed or torque limit can be performed For the external DC voltage use a DC power supply 0 to 10 VDC with reinforced insulation on its primary and secondary sides The input imp...

Страница 18: ...CN5 and IN COM1 Regeneration resistor AWG22 TH input IN COM1 150 C 302 F N C Connect to CN1 AWG18 R RG2 terminal RG1 terminal Note The TH input is not assigned to CN5 at the time of shipment When usi...

Страница 19: ...or in the clockwise direction 3 IN1 RVS This signal is used to rotate the motor in the counterclockwise direction 8 IN6 STOP This signal is used to stop the motor instantaneously 11 IN COM1 Input sign...

Страница 20: ...ince it rotates lightly Doing so may damage the product z z Setting with analog external setting devices Using PAVR 20KZ sold separately When using the PAVR 20KZ turn the M0 input ON Turning the PAVR...

Страница 21: ...key once again The display changes to 0 6 Operate the motor in JOG operation by pressing the key or key The operating speed is displayed during JOG operation The motor rotates in the clockwise directi...

Страница 22: ...arameter refer to the USER MANUAL When a power supply is turned on the speed of the monitor mode is displayed initial setting Use the monitor mode when operating the motor Monitor mode Speed Load fact...

Страница 23: ...r dielectric strength test on an encoder itself Doing so may damage the encoder Inspection item Check if any of the mounting screws of the motor and gearhead is loose Check if the bearing part ball be...

Страница 24: ...me Connect the regeneration resistor Undervoltage The power supply voltage dropped below approximately 60 of the rated voltage Check the voltage of the main power supply Check the wiring of the power...

Страница 25: ...ation data of different directions was linked in linked motion operation Five operation data or more was linked Positioning operation was performed at the operating speed of 0 r min Check the operatio...

Страница 26: ...rmissible voltage range 15 to 10 Rated frequency 50 60 Hz Permissible frequency range 5 Rated input current Single phase 3 7 A Single phase 2 3 A Three phase 1 1 A Single phase 4 7 A Single phase 2 8...

Страница 27: ...tegory Pollution degree 2 Protection against electric shock Class EMC Directive This product has received EMC compliance under the conditions specified in Example of installation and wiring on the USE...

Страница 28: ...ducts mentioned in this manual are recommended products and references to their names shall not be construed as any form of performance guarantee Oriental Motor is not liable whatsoever for the perfor...

Отзывы: