Installation
5 Installation
5.1 Installation location
The motor and driver are designed and manufactured to be incorporated in equipment.
Install them in a well-ventilated location that provides easy access for inspection. The location must also satisfy the
following conditions:
•
Inside an enclosure that is installed indoors (provide vent holes)
•
Operating ambient temperature: 0 to +50 °C (+32 to +122 °F) [non-freezing]
•
Operating ambient humidity 85% or less [non-condensing]
•
Area that is free of explosive atmosphere or toxic gas (such as sulfuric gas) or liquid
•
Area not exposed to direct sun
•
Area free of excessive amount of dust, iron particles or the like
•
Area not subject to splashing water (rain, water droplets), oil (oil droplets) or other liquids
•
Area free of excessive salt
•
Area not subject to continuous vibration or excessive shocks
•
Area free of excessive electromagnetic noise (from welders, power machinery, etc.)
•
Area free of radioactive materials, magnetic fields or vacuum
•
Altitude Up to 1000 m (3300 ft.) above sea level
5.2 Installing the driver
The driver is designed so that heat is dissipated via air convection and conduction through the enclosure.
Install the driver in a state where clearances of at least 25 mm (0.98 in.) in the horizontal and vertical directions between
the driver and enclosure or other equipment within the enclosure are provided.
Note
•
Install the driver in an enclosure whose pollution degree is 2 or better environment, or whose degree of protection is
IP54 minimum.
•
Do not install any equipment that generates a large amount of heat or noise near the driver.
•
Do not install the driver underneath the controller or other equipment vulnerable to heat.
•
If the ambient temperature of the driver exceeds the upper limit of the operating ambient temperature, reconsider
the ventilation condition or forcibly cool the area around the driver using a fan in order to keep within the operating
ambient temperature.
•
Be sure to install the driver vertically (in vertical position).
Installation conditions
Install the driver to a flat metal plate offering high heat conductivity [corresponding to an
aluminum plate of 200×200×2 mm (7.87x7.87x0.08 in.)].
When installing two or more drivers side by side, provide 20 mm (0.79 in.) and 25 mm (0.98 in.)
clearances in the horizontal and vertical directions, respectively.
•
Operating ambient temperature: 0 to +50 °C (+32 to +122 °F)
20 mm (0.79 in.)
or more
25 mm (0.98 in.)
or mor