Rejecting Incoming Calls
To reject all incoming calls on the Acme Packet 3900:
1.
In Superuser mode, type show sessions to see all the current calls.
ACMEPACKET# show sessions
2.
Type set-system-state offline and press Enter.
ACMEPACKET# set-system-state offline
Setting system state to going-offline, process will complete when
all current calls have completed
ACMEPACKET#
Shut Down the Acme Packet
1.
In Superuser mode, type halt.
2.
To confirm the halt request, type Y.
3.
When the console indicates shutdown is completed, unplug the AC power cords
from the power supplies on the rear panel.
4.
Confirm that all fans are off.
Rebooting, Resetting, and Power Cycling
Reboot
Rebooting the Acme Packet 3900 shuts down the system in an orderly fashion
and then automatically restarts it. The operating system gracefully shuts down as
processes are terminated and the file system is stopped. While the system and its
processes are stopped, all call processing is immediately halted. You may therefore
wish to perform tasks that call for a reboot during off-peak maintenance hours.
Rebooting the Acme Packet 3900 is required every time you upgrade with a new
version of the software.
Save your configurations before rebooting. Refer to the Maintenance and
Troubleshooting Guide for a full explanation of this procedure. The save-config
command is used to save the configuration in the example below.
To reboot:
1.
Type save-config to save any configuration changes you made.
ACMEPACKET# save-config
Save-Config received, processing.
waiting 1200 for request to finish
Request to 'SAVE-CONFIG' has Finished,
Save complete
Currently active and saved configurations do not match!
Chapter 5
Rebooting, Resetting, and Power Cycling
5-2