82
7-1-2 Controller
Z300-VC10EV3/Z300-VC15EV3
General Specifications
Model
Z300-VC10EV3
Z300-VC15EV3
Input/output type
NPN
PNP
Supply voltage
21.6 to 26.4 VDC (including ripple)
Current consumption
1A max. (with 2 Sensors connected) (See note 1.)
Insulation resistance
20 M
Ω
min. between all DC external terminals and GR terminal (100
VDC Megger, with internal surge absorber removed)
Dielectric strength
1,000 VAC, 50/60 Hz between all DC external terminals and GR ter-
minal (with internal surge absorber removed)
Leakage current
10mA max.
Noise resistance
1,500 Vp-p; Pulse width: 0.1µs/1µs;Rising edge: 1-ns pulse
Vibration resistance
10 to 150 Hz (double amplitude: 0.1 mm) for 8 min each in X, Y, and
Z directions
Shock resistance
200m/s
2
, 3 times each in 6 directions
Ambient temperature
Operating: 0 to +50
°
C (with no icing or condensation)
Storage: -15 to +60
°
C (with no icing or condensation)
Ambient humidity
Operating and storage: 35% to 85% (with no condensation)
Ambient environment
No corrosive gases
Ground
Ground the Z300’s ground terminal to less than 100
Ω
Degree of protection
IEC60529 IP20 (in-panel)
Case material
Controller: ABS
195
83.7
20.2
Indicators
10
10
98.1
24.5 20
185
81.71
23.6
75.5
87.9
3.85
148.38
3.85
99.5
Four, 4.5 dia.holes
(Unit: mm)
Connector
(32.5)
4.1
(66.5)
8
50
44.8
110
100
90
35.3
25.1
53.1
36.2
8
4
23.3
12.5dia.
8 7.7=61.6
9 7.7=69.3
9
7.7=69.3
9 7.7=69.3
2 7.62=15.24
Controller
Section 7-1
Содержание Z300 V3 - SETUP
Страница 3: ...2 ...
Страница 7: ...6 ...
Страница 21: ...20 ...
Страница 59: ...58 Long range Model Z300 S10 Super Long range Model Z300 S60 Mounting the Sensor Section 3 2 ...
Страница 62: ...61 Z300 S10 Z300 S60 Mounting the Sensor Section 3 2 ...
Страница 63: ...62 ...
Страница 69: ...68 DIP Switch Settings Section 4 2 ...
Страница 72: ...71 SECTION 5 Maintenance This section explains maintenance procedures for ensuring the Z300 s performance ...
Страница 77: ...76 ...
Страница 80: ...79 Z300 S10 Z300 S60 42 8 12 5dia 42 8 12 5dia Sensor Section 7 1 ...