56
Rotating Workpieces
When measuring rotating workpieces, the influence of position displacement
and blurring of the rotating workpiece can be minimized by mounting the Sensor
so that the plane containing the emission axis and the reception axis is parallel
to the axis of rotation.
Thickness Measurement
When measuring the thickness of boards, select the Sensor mounting method
according to the board material.
Workpiece
Opaque
Transparent
Example: Glass
Diffuse reflection
Example: Ceramic
Specular reflec-
tion Example:
Stainless steel
Sensor mounting
status
Diffuse reflection
mounting status
Mirror reflection mounting status
Controller settings
Workpiece
Workpiece
Mounting the Sensor
Section 3-2
Содержание Z300 V3 - SETUP
Страница 3: ...2 ...
Страница 7: ...6 ...
Страница 21: ...20 ...
Страница 59: ...58 Long range Model Z300 S10 Super Long range Model Z300 S60 Mounting the Sensor Section 3 2 ...
Страница 62: ...61 Z300 S10 Z300 S60 Mounting the Sensor Section 3 2 ...
Страница 63: ...62 ...
Страница 69: ...68 DIP Switch Settings Section 4 2 ...
Страница 72: ...71 SECTION 5 Maintenance This section explains maintenance procedures for ensuring the Z300 s performance ...
Страница 77: ...76 ...
Страница 80: ...79 Z300 S10 Z300 S60 42 8 12 5dia 42 8 12 5dia Sensor Section 7 1 ...