2-5-4 Terminal Applications
Output Terminals
Input Terminals
Notice
- Do not reverse the connections of the signal terminals and COM terminals.
- Do not input the RESET input immediately after turning ON the power.
When using RESET input to synchronize startup timing, wait at least 1 s after
turning ON the Z300's power supply before turning ON the RESET terminal.
CHECK
- The initial status of the output terminals is OFF. The terminals, however,
may turn ON for approximately 0.5 s when the power is turned ON. Be sure
to allow for this when connecting to an external device.
Name
Application
Name
Application
DO 0
Measurement results out-
put
DO 14
Measurement results out-
put
DO 1
DO 15
DO 2
DO 16
DO 3
DO 17
DO 4
DO 18
DO 5
DO 19
DO 6
GATE
Control terminals
For details, refer to page
150 in the Operation Man-
ual.
DO 7
DO 8
COM OUT
(*1)
Common for DO 16 to 19
and GATE
DO 9
DO 10
COM OUT
(*2)
Common for DO 0 to 7
DO 11
DO 12
COM
OUT(*3)
Common for DO 8 to 15
DO 13
Name
Application
HOLD RST
Control terminals
For details, refer to page 150 in the Operation
Manual.
LD OFF
TRIGGER
ALL ZERO
ZERO 0
ZERO 1
DI 0
Command input
DI 1
DI 2
DI 3
RESET
For resetting the Z300
COMIN
Common for all input terminals
Terminal Block Connections
Section 2-5
Содержание Z300 V3 - SETUP
Страница 3: ...2 ...
Страница 7: ...6 ...
Страница 21: ...20 ...
Страница 59: ...58 Long range Model Z300 S10 Super Long range Model Z300 S60 Mounting the Sensor Section 3 2 ...
Страница 62: ...61 Z300 S10 Z300 S60 Mounting the Sensor Section 3 2 ...
Страница 63: ...62 ...
Страница 69: ...68 DIP Switch Settings Section 4 2 ...
Страница 72: ...71 SECTION 5 Maintenance This section explains maintenance procedures for ensuring the Z300 s performance ...
Страница 77: ...76 ...
Страница 80: ...79 Z300 S10 Z300 S60 42 8 12 5dia 42 8 12 5dia Sensor Section 7 1 ...