50
3-2 Mounting the Sensor
Up to 2 Sensors can be connected per Controller. When using the Z300 in Non-
visual Mode, however, only 1 Sensor can be connected.
WARNING
Do not to expose your eyes to the laser radiation either directly or indi-
rectly (i.e., after reflection from a mirror or shiny surface). The laser radia-
tion has a high power density and exposure may result in loss of sight.
Notice
Only sensors specifically for the Z300 can be used.
Using another type of sensor may result in damage to the sensor or controller.
3-2-1 Sensor Types
Reference
distance
(A)
Measure-
ment
range
(B)
Spot diameter
(C)
Line beam width
(D)
Super-precision
Model: Z300-S2T
20mm
±1mm
B=-1mm : 50µm
B=0mm : 20µm
B=+1mm : 50µm
0.3mm
(The width of the measurement
region is 0.2 mm)
High-precision
Model: Z300-S5T
50mm
±5mm
B=-5mm : 140µm
B=0mm : 30µm
B=+5mm : 140µm
0.4mm
Long-range Model:
Z300-S10
100mm
±20mm
B=-20mm : 280µm
B=0mm : 60µm
B=+20mm : 280µm
1.0mm
Super Long-range
Model: Z300-S60
600mm
±350mm
B=-350mm : 0.8mm
B=0mm : 0.4mm
B=+350mm : 1.3mm
B=-350mm : 10mm
(The width of the measurement
region is 5.0mm)
B=0mm : 18mm
(The width of the measurement
region is 12.4mm)
B=+350mm : 26mm
(The width of the measurement
region is 20mm)
Line beam
D
C
A
B
Front View
Z300-S2T/S5T/S10
Line beam
D
Z300-S60
View in the direction of the arrows
Mounting the Sensor
Section 3-2
Содержание Z300 V3 - SETUP
Страница 3: ...2 ...
Страница 7: ...6 ...
Страница 21: ...20 ...
Страница 59: ...58 Long range Model Z300 S10 Super Long range Model Z300 S60 Mounting the Sensor Section 3 2 ...
Страница 62: ...61 Z300 S10 Z300 S60 Mounting the Sensor Section 3 2 ...
Страница 63: ...62 ...
Страница 69: ...68 DIP Switch Settings Section 4 2 ...
Страница 72: ...71 SECTION 5 Maintenance This section explains maintenance procedures for ensuring the Z300 s performance ...
Страница 77: ...76 ...
Страница 80: ...79 Z300 S10 Z300 S60 42 8 12 5dia 42 8 12 5dia Sensor Section 7 1 ...