83
Performance specifications
Note 1:
Average current at normal operation after power is turned ON.
Note 2:
For measurement at an average number of times of 64 with an OMRON K3AS
Linear Sensor Controller connected.
Item
Visual Mode
Non-visual Mode
Number of Sensors
that can be mounted
2
1
Number of scenes
16
1
Image memory func-
tion
NG images: 20 scenes max.; Surrounding
images: 4 scenes max.; Workpiece display
images: 4 scenes max.
——
Processing method
Gray center of gravity, edge centering
Edge centering
Pre-image processing
Noise removal, smoothing
None
Averaging/filtering
Average number of times (12 stages, 1 to 4,096
times), HPF (high pass filter), Median
Average number of times
(SLOW: 64 times; FAST:
1 time)
Light intensity track-
ing function
Automatic (The light intensity tracking range can
be specified.)
Fixed (Select from 32 stages.)
Automatic (The light
intensity tracking range
can not be specified.)
Fixed (Select either HIGH
or LOW.)
Applications
Select from the following 8 types:
Surface displacement, spot displacement, maxi-
mum height, groove/indentation, level difference,
transparent workpiece thickness, level difference
(2 Sensors), or thickness (2 Sensors).
——
Region specification
Region specification of line beam and displace-
ment direction is possible.
——
Two region measure-
ment modes
Absolute coordinate mode and relative coordi-
nate mode
——
Hold functions
Sampling, peak, bottom, peak-to-peak, average,
and length
——
Two Sensor measure-
ment modes
Simultaneous measurement and alternate mea-
surement
——
Measurement data
4 outputs per scene
1 output
Equations
The following operations are possible for outputs
0 to 3:
K+A, K-A, K+(A+B), K+(A-B), and K-(A+B)
A and B: Specified measurement points
K: Freed constant
——
Results output
Judgement output (HIGH, PASS, LOW, ERROR)
RS-232C output
Terminal block output
Measurement value output (measurement value)
RS-232C output
Terminal block output
Analog output
Analog output
Terminal block
11 input points:TRIGGER, HOLD-RESET, LD-
OFF, ALL-ZERO, ZERO0, ZERO1, RESET, and
DI 0 to DI 3
21 output points: DO0 to DO20
LD-OFF
Monitor interface
1 channel (for pin jack or overscan monitor)
——
Analog output resolu-
tion
The full scale for output can be divided into a maximum of 40,000 gradations.
Resolution (See note 2.) *0.25 mV (±5V)
0.4µA (4 to 20µA)
Weight
Approx. 700 g (Controller only)
Controller
Section 7-1
Содержание Z300 V3 - SETUP
Страница 3: ...2 ...
Страница 7: ...6 ...
Страница 21: ...20 ...
Страница 59: ...58 Long range Model Z300 S10 Super Long range Model Z300 S60 Mounting the Sensor Section 3 2 ...
Страница 62: ...61 Z300 S10 Z300 S60 Mounting the Sensor Section 3 2 ...
Страница 63: ...62 ...
Страница 69: ...68 DIP Switch Settings Section 4 2 ...
Страница 72: ...71 SECTION 5 Maintenance This section explains maintenance procedures for ensuring the Z300 s performance ...
Страница 77: ...76 ...
Страница 80: ...79 Z300 S10 Z300 S60 42 8 12 5dia 42 8 12 5dia Sensor Section 7 1 ...