Command and Response Frame Structures
Section 5-2
5-8
1) Correlation table of ISO/IEC Error Codes
When a Tag incorporating ISO/IEC chip (including I.CODE2 chip) returns an error response, the
Reader/Writer responses a Response Code shown in the table below.
ISO code
Description
Response code of module
01
An unadopted command. No request command can be
recognized.
79
02
An unrecognizable command. ex. format error.
79
03
An unadopted arbitrary command
79
0F
An unaccountable error or unadopted error code.
79
10
A specific block cannot be use. (There is none)
7A
11
A specific block cannot be relocked since the block has
been already locked.
00
12
A specific block cannot be rewritten since it is locked.
71
13
A specific block has not completed writing correctly.
71
14
A specific block has not completed locking correctly.
71
Others RFU
79
5-2-5 Example BCC Calculation
BCC is the result of the horizontal parity calculation of the data right after STX up to ETX inclusive.
Refer to JIS5001 Transmission Path Character Configuration and Using Horizontal Parity for details.
Node No.
Command
code
Text
BCC
STX
0 0 R D S T A 0 0 0 0 1
ETX
62
Command data
ASCII code data
0 0011
0000
EOR
0 0011
0000
EOR
R 0101
0010
EOR
D 0100
0100
EOR
S 0101
0011
EOR
T 0101
0100
EOR
A 0100
0001
EOR
0 0011
0000
EOR
0 0011
0000
EOR
0 0011
0000
EOR
0 0011
0000
EOR
1 0011
0001
EOR
ETX 0000 0011
Calculation
results
0110 0010
Содержание V720S Series
Страница 3: ...ii ...
Страница 57: ...Wiring Method Section 4 4 4 18 ...
Страница 133: ...7 1 SECTION 7 Reference Data 7 1 Communications Time 7 2 7 2 Calculation of Tag Traveling Speed 7 4 ...
Страница 137: ...8 1 SECTION 8 Appendix Appendix 1 Accessories 8 2 Appendix 2 ASCII Code Table 8 3 ...
Страница 140: ...ASCII Code Table Section Appendix 2 8 4 ...