Setting Command
Section 5-6
5-43
<Response Format>
STX
Node No.
Retry
flag
Command
code
"CP"
Response
code:
"00"
Port
No.
Baud
rate
Data
length
Parity
bit
Stop
bit
BCC
Enabled
/Disabled
ACK
NACK
Time-
out
ETX BCC
1
2
1
2
2
1 1 1 1 1 1 1 1 1 1
Response code:
00: Normal completion
For other response codes, refer to 5-10 Response Code List.
Port No.
Indicates the number corresponding to the specified terminal resistance.
Baud rate
Indicates the number corresponding to the specified baud rate.
Data length
Indicates the number corresponding to the specified data length.
Parity bit
Indicates the number corresponding to the specified parity bit.
Stop bit
Indicates the number corresponding to the specified stop bit.
BCC
Enabled/Disabled
Indicates the number corresponding to the specified BCC setting.
ACK/NACK
Indicates the number corresponding to the specified control mode.
Timeout
Indicates the number corresponding to the specified timeout period.
Note
•
The setting becomes effective after resetting using the Reset Command.
•
In order to make your setting survive system shutdown, you need to save
the Setting Write Command (refer to EW Command in 10, 5-2-4) in the
EEPROM..
5-6-8 Communications Type Setting (CT)
This command selects whether COM1 will be used as RS-232C or RS-485.
<Command Format>
STX
Node No.
Command
code
"CT"
Commni-
cations
type
ETX BCC
1 2
2 1 1
1
Specify the number corresponding to the communications type
that you want to select.
Specification range: 0, 1, *
When * is specified, the Reader/Writer reads the current setting.
Specification
number
0 1
*
Communications
type
Communica-
tions type
RS232C RS485
-
<Response Format>
STX Node
No. Retry
flag
Command
code
"CT"
Response
code:
"00"
Commu-
nications
type
ETX BCC
1 2 1 2
2 1
1
1
Response code
00: Normal completion
For other response codes, refer to 5-10 Response Code List.
Terminal setting
Indicates the number corresponding to the specified terminal resistance.
Note
•
The setting becomes effective after resetting using the Reset Command.
•
In order to make your setting survive system shutdown, you need to save
the Setting Write Command (refer to EW Command in 10, 5-2-4) in the
EEPROM..
Содержание V720S Series
Страница 3: ...ii ...
Страница 57: ...Wiring Method Section 4 4 4 18 ...
Страница 133: ...7 1 SECTION 7 Reference Data 7 1 Communications Time 7 2 7 2 Calculation of Tag Traveling Speed 7 4 ...
Страница 137: ...8 1 SECTION 8 Appendix Appendix 1 Accessories 8 2 Appendix 2 ASCII Code Table 8 3 ...
Страница 140: ...ASCII Code Table Section Appendix 2 8 4 ...