Setting Command
Section 5-6
5-42
5-6-7 Communications Port Setting Command (CP)
This command sets the baud rate for the communications port (COM Port), data length, parity bit,
and stop bit for use in communications with the host.
<Command Format>
STX
Node No.
Command
code
"CP"
Port
No.
Baud
rate
Data
length
Parity
bit
Stop
bit
BCC
Enabled
/Disabled
ACK
NACK
time-
out
ETX BCC
1 2
2 1
1
1
1
1
1
1
1
1
1
Port No.
Specify the port number that you want to change in decimal.
Specification range:
1
or 2
Specification number
1
2
Port COM1
COM2
Specify the number corresponding to the baud rate that you want to change.
Specification range: 0 to 3, *
When * is specified, the Reader/Writer reads the current setting.
Specified
number 0
1
2
3
*
Baud rate
Baud rate
9600 bps
19200 bps
38400 bps
115200 bps
-
Data length
Specify the number corresponding to the data length that you want to change.
Specification range: 0, 1, *
When * is specified, the Reader/Writer reads the current setting.
Specification number
0
1
*
Data length
7Bit
8Bit
-
Specify the number corresponding to the parity bit that you want to change.
Specification range: 0, 1, 2, *
When * is specified, the Reader/Writer reads the current setting.
Specification
number
0 1 2 *
Parity bit
Parity No
Odd Even -
Stop bit
Specify the number corresponding to the stop bit that you want to change.
Specification range: 0, 1, *
When * is specified, the Reader/Writer reads the current setting.
Specification number 0
1
*
Stop bit
1 bit 2 bits
-
BCC En-
abled/Disabled
Specify the number corresponding to the BCC setting that you want to change.
Specification range: 0, 1, *
When * is specified, the Reader/Writer reads the current setting.
Specification number
0
1
*
BCC
Enabled
Disabled
-
ACK/NACK
Specify the number corresponding to the communications mode that you want
to change.
Specification range: 0, 1, *
When * is specified, the Reader/Writer reads the current setting.
Specification number
0
1
*
ACK/NACK Control
Disabled
Enabled
-
Timeout
ACK/NACK timeout
period setting
Specify the number corresponding to the timeout period that you want to
change.
Specification range: 0, 1, *
When * is specified, the Reader/Writer reads the current setting.
Specification number
0
1
*
Timeout period
5 sec
0.5 sec
-
Содержание V720S Series
Страница 3: ...ii ...
Страница 57: ...Wiring Method Section 4 4 4 18 ...
Страница 133: ...7 1 SECTION 7 Reference Data 7 1 Communications Time 7 2 7 2 Calculation of Tag Traveling Speed 7 4 ...
Страница 137: ...8 1 SECTION 8 Appendix Appendix 1 Accessories 8 2 Appendix 2 ASCII Code Table 8 3 ...
Страница 140: ...ASCII Code Table Section Appendix 2 8 4 ...