background image

 

 

Written by Liam Lin 

Edited by Janice Hong

 
 

I

ndust ri al

 C

omputer

 P

roducts

 

D

ata

 A

cquisi ti on

 S

yste ms

 

 

 

 

 

 

 

 

 

MQ-7200M  Series     

User  Manual   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

e

rs

io

n

 1

.0.

1

M

ay

20
23

 

Содержание MQ-7200M Series

Страница 1: ...Written by Liam Lin Edited by Janice Hong Industrial Computer Products Data Acquisition Systems MQ 7200M Series User Manual Version 1 0 1 May 2023...

Страница 2: ...without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use nor for any infringements of patents or other r...

Страница 3: ...252M 14 2 4 MQ 7253M 16 2 5 MQ 7255M 17 3 Getting Started 19 3 1 Cabling Power and Network 20 3 2 Installing the MiniOS7 Utility 21 3 3 Configuring Network Settings 22 3 4 Logging in to Web Interface...

Страница 4: ...us of the MQ 7200M 46 7 3 Controlling the DO Status of the MQ 7200M 49 8 Frequently Asked Question FAQ 51 8 1 Establishing a Connection by Using MiniOS7 Utility 51 8 2 Exchanging the Protocol TCP IP t...

Страница 5: ...the user to configure module and control monitor the status of digital I O by simply using a regular web browser Support for MQTT protocol makes it easy to connect sensors to Internet of Things IoT s...

Страница 6: ...ications because of its small size low power usage minimized data packets and efficient distribution of information to one or many receivers Built in I O Various I O components are mixed with multiple...

Страница 7: ...and the MQ 7200M When the MQ 7200M is disconnected from the MQTT broker for a while the watchdog forces the digital output to pre defined Safe Value to prevent unpredictable damage of the connected d...

Страница 8: ...Pressing and holding the reset button for at least 3 seconds will restore the module to its factory defaults For more information see section 7 4 How to restore MQ 7200M to default settings LED indica...

Страница 9: ...e E1 port E2 On A link has been established on the E2 port Off No link is established on the E2 port Flashing Data is now transferred via the E2 port I O Indictors The number of I O will vary dependin...

Страница 10: ...MQ 7200M User Manual version 1 0 1 Page 10 1 3 Dimensions Unit mm Left Side View Top View Front View Bottom View...

Страница 11: ...DC Off Voltage Level 4 VDC max Input Impedance 10 K Overvoltage Protection 70 VDC Digital Output Channels 8 Type Isolated Open Collector Sink Source NPN PNP Sink Max Load Current 650 mA Channel at 25...

Страница 12: ...ersion 1 0 1 Page 12 Pin Assignments Wire Connections Digital Input Readback as 1 Readback as 0 Sink 10 50 VDC Open or 4 VDC Source Digital Output ON State Readback as 1 OFF State Readback as 0 Drive...

Страница 13: ...nput Channels 16 Type Wet Contact Sink Source NPN PNP Sink Source On Voltage Level 10 VDC 50VDC Off Voltage Level 4 VDC max Input Impedance 10 K Overvoltage Protection 70 VD Pin Assignments Wire Conne...

Страница 14: ...C Off Voltage Level 4 VDC max Input Impedance 10 K Overvoltage Protection 70 VDC Digital Output Channels 8 Type Isolated Open Collector Sink Source NPN PNP Source Max Load Current 650 mA Channel at 25...

Страница 15: ...7200M User Manual version 1 0 1 Page 15 Wire Connections Digital Input Readback as 1 Readback as 0 Sink 10 50 VDC Open or 4 VDC Source Digital Output ON State Readback as 1 Source OFF State Readback a...

Страница 16: ...ital Input Channels 16 Type Dry Contact Sink Source NPN PNP Source On Voltage Level Close to GND Off Voltage Level Open Overvoltage Protection Effective Distance 500 M Max Pin Assignments Wire Connect...

Страница 17: ...VDC Off Voltage Level 4 VDC max Dry Contact On Voltage Level Close to GND Off Voltage Level Open Input Impedance 10 K Overvoltage Protection 70 VDC Digital Output Channels 8 Type Isolated Open Collect...

Страница 18: ...ections Digital Input Readback as 1 Readback as 0 Wet Contact Sink 10 50 VDC Open or 4 VDC Wet Contact Source Digital Input ON State Readback as 1 OFF State Readback as 0 Dry Contact Digital Output ON...

Страница 19: ...s in the BOX Before starting any task please check the package contents If any of the following items are either missing or damaged contact the dealer or distributor MQ 7200M Module Quick Start Guide...

Страница 20: ...twork Step 1 Connect the computer to the Ethernet Port via the Hub or Switch Step 2 Connect the positive of the power supply to the terminal marked R Vs Connect the negative of the power supply to the...

Страница 21: ...ed a new shortcut for the MiniOS7 Utility will be displayed on the desktop Step 1 Install the MiniOS7 Utility tool The latest version of the MiniOS7 Utility can be obtained from the ICP DAS website ht...

Страница 22: ...e table below Before starting the MQ 7200M valid network settings for the LAN where the module will operate need be set to the module Default Ethernet Settings Item Default IP Address 192 168 255 1 Su...

Страница 23: ...rch for the module Step 3 Click the 192 168 255 1 in the IP Port field and click the IP Settings button Click the item you want to configure the default IP 192 168 255 1 and then click the IP Settings...

Страница 24: ...es and alias Alternatively the user can enable the DHCP Client function to dynamically obtain an IP address from the DHCP Server After entering the appropriate values click the Set button to update th...

Страница 25: ...Step 1 Launch the browser The user can use a standard web browser such as Mozilla Firefox or Internet Explorer to log in to the MQ 7200M module Step 2 Enter the IP address for the MQ 7200M If the user...

Страница 26: ...1 Page 26 Step 4 Welcome to the MQ 7200M web interface After logging into the module the Overview page provides a brief description of the module including its MAC address the current firmware versio...

Страница 27: ...itor the I O status through a web browser Before starting the configuration steps please refer to Chapter 3 Getting Started to configure and log in to the MQ 7200M module Step 1 Welcome to the MQ 7200...

Страница 28: ...uration In the Configure dropdown menu there are two ways to configure the network Manual configuration Manually If DHCP is not available you can manually set up the IP address subnet mask and gateway...

Страница 29: ...m that is used to connect a network with one or more other networks DNS Server DNS stands for domain name system whose main function is to translate domain names e g www icpdas com to IP addresses and...

Страница 30: ...st line and Page Header Information Second line The title of the website that is displayed at the top left hand corner of the interface for example the company name and web address as per the example...

Страница 31: ...ower loss caused by either a normal or abnormal event is crucial to prevent accidents In addition in the case of host failure or network communication exceptions it is equally important to output a sa...

Страница 32: ...its power on value Method After selecting On or Off clicking the Apply button to complete the setting Safe Value The user can set the safe value for each output channel In the event of a communicatio...

Страница 33: ...tion from the official MQTT org The MQ 7200M module as an MQTT client can publish messages for DIO status to the broker and subscribe to control messages for DO Similarly other MQTT clients also can s...

Страница 34: ...e Last Will and Testament for announcing a module s offline message and obtain the topic names for each I O MQTT conversation The user can enable disable the MQTT function If the MQTT conversation is...

Страница 35: ...fier The identifier for each MQTT Client to connect to the MQTT Broker must be unique It is composed of the module name the underline character and the last 6 digits of the MAC address and cannot be m...

Страница 36: ...end within the specified Keep Alive Interval it is required to send a PINGREQ packet to the Broker while the Broker must reply with a PINGRESP packet If the Client fails to send a PINGREQ or any other...

Страница 37: ...cribed to this Offline topic Method 1 To enable this function tick the Last Will and Testament box 2 Enter the topic name Topic and the LWT message Data and select the Quality of Service QoS for messa...

Страница 38: ...n be published to topics based on either a time driven or event driven approach Time driven The I O status is regularly published at specific intervals 10 600 seconds which can be configured in the Pe...

Страница 39: ...the MQTT conversation feature is enabled the MQ 7200M will automatically subscribe to all DO topics upon startup Digital Outputs Digital Inputs A topic for each I O channel on a MQ 7200M module consi...

Страница 40: ...message to control the output and the MQ 7200M will carry out the output command GetValue Published topic The client can subscribes to this topic to receive the I O status published by the MQ 7200M Le...

Страница 41: ...The user can configure the published condition for each I O Stop publishing Stop publishing the I O status Periodically publish The I O status will be published periodically Publish only on status cha...

Страница 42: ...ide both a username and password Authentication is enabled by default User Management The factory default employs the administrator account and you can establish an additional administrator or user ac...

Страница 43: ...on status between the PC and the MQ 7200M module 2 Connection status between the MQ 7200M module and the broker you set 3 The status of each I O channel The user can control the output channels by cli...

Страница 44: ...7200M 1 On the MQTT page make sure that the MQTT function is enabled 2 Enter both the URL and port number of the Broker and click the Apply button to update the settings In the example we use the Hiv...

Страница 45: ...4 On the Web HMI page the user can verify if the connection is successful If the connection between the MQ 7200M and the MQTT broker is established successful all the topics listed on this page will...

Страница 46: ...QTT client on your PC MQTT Lens is a Chrome extension tool that lets you publish messages to an MQTT broker subscribe to MQTT topics and receive messages using the chrome web browser 1 Install the MQT...

Страница 47: ...button to add a connection enter a name e g Broker01 in the Connection Name field enter a hostname e g broker hivemq com in the Hostname field and click the Create Connection button 4 Enter the topic...

Страница 48: ...Page 48 5 The user can all topics listed on the Web HMI page to the subscriptions Next click the ON OFF button to change the status of the I O and view the subscribed messages Change the status of th...

Страница 49: ...lished 3 Confirm that the MQTT Client software MQTT Lens has been installed and the connection between it and the broker has been established Refer to Section 7 2 Steps 1 to 3 https chrome google com...

Страница 50: ...field of the MQTT Lens enter the Topic name F001 Set_Value DO_0 and the Message 1 and then click the Publish button Now the user can observe that the DO0 indicator of the MQ 7200M has been switched o...

Страница 51: ...MiniOS7 with easiness and quickness If the MiniOS7 Utility is not yet installed on the system installation of the MiniOS7 Utility should be the first step Please refer to section 3 2 Installing the Mi...

Страница 52: ...iniOS7 utility performs a search of all modules on the network Step 3 Click the IP address in the IP Port field list and then click the Connect icon in the toolbar After the search has been completed...

Страница 53: ...age 53 Step 4 Check the connection symbol to make sure that the connection is established Check the connection symbol status in the top right side to make sure the connection has been established Conn...

Страница 54: ...o the MQ 7200M Refer to section 8 1 Establishing a Connection for more information Step 2 Stop the firmware running Right click the file list of the right side windows and then choose Quit Firmware to...

Страница 55: ...php num 2678 8 3 1 Using the MiniOS7 Utility Step 1 Establish a connection to MQ 7200M Be sure that the MiniOS7 Utility is connecting with the MQ 7200M using the UDP connection For a more detailed des...

Страница 56: ...ill appear Please select the most recent version of the MiniOS7 OS image Step 4 Click OK to finish the procedure After confirming the command the user just need to wait awhile until the following dial...

Страница 57: ...n For a more detailed description of this instruction refer to the section 8 2 Exchanging the Protocol TCP IP to UDP Step 2 Choose the location where the MinisOS7 image file is stored Step 3 Connect t...

Страница 58: ...the bios1 command to update the image to the flash The MQ 7200M will automatically restart after the update is completed The user can perform another search for the module to check if the TCP connecti...

Страница 59: ...ow php num 2677 Step 1 Establish a connection to connection to the MQ 7200M Be sure that the MiniOS7 Utility is connecting with the MQ 7200M using the UDP connection For a more detailed description of...

Страница 60: ...n the Confirm dialog box click the Yes button to continue After executing the Erase Disk command the Confirm dialog will appear and then click Yes button to continue erasing the memory contents Step 4...

Страница 61: ...MQ 7200M User Manual version 1 0 1 Page 61 Step 5 Reboot the module After the update is completed reboot the module...

Страница 62: ...ult Settings IP Address 192 168 255 1 Gateway 192 168 0 1 Subnet Mask 255 255 0 0 DNS Server Empty DHCP Disabled Web Configuration Item Factory Default Settings Module Name Depends on the name of the...

Страница 63: ...0040 0045 6 DI value 0 Off 1 On R 00126 007E 1 Reset the I O settings to the factory default state 1 Reset W 00133 0085 1 Reboot the module 1 Reboot W 00235 00240 00EB 00F0 6 Enable Disable the DO po...

Страница 64: ...2 3 R 30153 0099 1 1 I O version 0x123 means version 1 2 3 R Holding Register 4xxxx Register Points No Per Point Description Data Format Attribute Factory Value DEC HEX 40255 00FF 1 1 Read the module...

Страница 65: ...sibly crashed Reboot the module Cannot communicate via the Ethernet port but the MQ 7200M is still operating The IP Mask Gateway address isn t within the IP address range of the LAN Change the IP Mask...

Страница 66: ...on 1 0 1 Page 66 Revision History The table below shows the revision history Revision Date Description 1 0 0 Aug 2016 Initial issue 1 0 0 Jun 2023 Adjust the order of chapters add or modify some chapt...