Timeslot Setting
Section 5-10
5-63
5-10 Timeslot Setting
The timeslot setting is the setting in the command frame when communicating with multiple Tags
simultaneously using Multi-system commands. This setting must be set according to the number of
Tags with which to communicate simultaneously. Refer to the table below for the relationship be-
tween the number of Tags and this setting.
Timeslot setting
Max. No. of Tags with which simultaneous communi-
cation is possible
0 1
1
~
2
2
~
4
3
~
8
4
~
16
5
~
32
6
~
64
7
~
128
Example: If the number of Tags is seven, select Tag Number setting 3.
Note
•
If more Tags than have been set using the timeslot setting enter the
communications range, a "70" error (warning) may occur. (e.g., When
the timeslot setting is "2" and there are five Tags in the communications
area.)
Select a suitable setting by referring to the above table.
•
For the Special Read (refer to 5-2-1-6) command, the anti-collision proc-
ess is not performed. Therefore, read data will be returned even If there
are more Tags than the timeslot setting in the communications area.If a
collision occurs, such data will not be returned.
•
The higher the timeslot setting is, the longer the communications time is
required. Consequently, setting a higher timeslot setting than required for
the number of Tags in use unnecessarily lengthens communications time,
so select a suitable setting.
Содержание V720S Series
Страница 3: ...ii ...
Страница 57: ...Wiring Method Section 4 4 4 18 ...
Страница 133: ...7 1 SECTION 7 Reference Data 7 1 Communications Time 7 2 7 2 Calculation of Tag Traveling Speed 7 4 ...
Страница 137: ...8 1 SECTION 8 Appendix Appendix 1 Accessories 8 2 Appendix 2 ASCII Code Table 8 3 ...
Страница 140: ...ASCII Code Table Section Appendix 2 8 4 ...