Setting Command
Section 5-6
5-49
5-6-15 Operating Mode Changeover (TY)
This command changes the operating mode (ISO/I.CODE1) of the Reader/Writer.
<Command Format>
STX
Node No..
Command code
“TY”
Tag
type
ETX BCC
1 2
2 1
1
1
Tag type
Specifies the mode.
0: I.CODE1 mode
1: ISO mode
When the Operating Mode is set to "**," the Operating Mode currently set in
the Reader/Writer will be read.
<Response Format>
STX Node
No.. Retry
flag
Command code
“TY”
Response
code
“00”
Tag
type
ETX BCC
1 2 1 2
2 1
1
1
Response code
00:normal completion
For other response codes, refer to 5-2-4 Response code List.
Tag type
Specifies the mode.
Note
A setting becomes valid after executing Reset Command. To keep the set-
ting valid next startup, you need to save with Setting Write Command (refer
to 5-6-14 EW Command).