267
V530-R160
Operation Manual
SECTIO
N
10
Maint
e
na
nce
SECTION 10
SECTIO
N
10
SECTION 10
Appendix
Regular Inspections
To maintain the V530-R160 in the best condition, perform the following regularly.
Clean the Lens and LED indicators with a lens-cleaning wipe or blow off dust with an aerosol air
sprayer.
Lightly wipe off dirt with a soft cloth.
• Turn OFF the power and take safety precautions before conducting inspections.
• Do not use thinners or benzene.
Inspection point
Details
Tools required
Power supply
The voltage measured at the power supply terminals on
the terminal block must be 20.4 VDC to 26.4 VDC.
Circuit tester
Ambient temperature
The operating ambient temperature inside the cabinet
must be between 0 to 50
°
C.
Thermometer
Ambient humidity
The operating ambient humidity inside the cabinet must be
between 35 and 85%.
Hygrometer
Installation
Each cable connector must be correctly inserted and
locked.
The cameras must be firmly secured.
The camera lens mounts must be firmly secured.
Screwdriver
LED lights
All indicators must light when the power is turned ON.
• Verify that a through-image is displayed.
• When using an Intelligent Lighting, verify that the light
level settings are set to their maximum values.
−
Содержание V530-R160E
Страница 36: ...34 SECTION 1 Operational Flow V530 R160 Operation Manual SECTION 1 Outline MEMO...
Страница 144: ...142 SECTION 5 Setting Reading Conditions QRCode V530 R160 Operation Manual SECTION 5 Setting Reading Conditions MEMO...
Страница 192: ...190 SECTION 7 Checking the Version Version V530 R160 Operation Manual SECTION 7 System Settings MEMO...
Страница 250: ...248 SECTION 8 Serial Interface Host Link V530 R160 Operation Manual SECTION 8 Communication with the Host MEMO...
Страница 288: ...286 SECTION 10 Glossary SECTION 10 V530 R160 Operation Manual SECTION 10 Appendix MEMO...