101
V530-R160
Operation Manual
SECTION
5
Adjust
in
g t
h
e Imag
e
(Image
Adjus
t)
SECTION 5
Setting Reading Conditions
Light Control Screen
A. Segment display
Lighting can be adjusted in 5 areas.
The reading points are displayed with thick lines. The brightness depends on the set light level.
Refer to page 102.
B. Light volume
The light level setting for each area is shown in a separate digit of the 5-digit number. The light
level settings range from 0 to 7; a value of 0 is OFF and 7 is the maximum brightness.
C. Sample lighting pattern number
There are 15 sample lighting patterns registered in the V530-R160.
Refer to page 102.
B. Light volume
A. Segment display
C. Sample lighting pattern number
As viewed from
this perspective
C
D
B
A
E
5 Areas
3 3 3 3 3
Light level for area A
Light level for area B
Light level for area E
Light level for area D
Light level for area C
Lighting pattern: