SECTION 8
Communication with the Host
Format
The format is explained here in command code order. The commands are input in BCD code. Set
the command in the reading word of the Read Area.
0010: One shot reading
Function • • • Performs one reading.
Reading ends when the reading is correctly performed (OK).
When the reading is not correctly performed (NG), reading continues to be per-
formed for the number of retries specified in the setting conditions.
The reading result is output to the Write Area.
Refer to page 243.
0011: Continuous reading
Function • • • Performs continuous reading.
The reading result is output to the Write Area.
Refer to page 243.
0012: Continuous reading stop
Function • • • Stops continuous reading.
Reading start word
Data
Description
+0
0
0
1
0
Command code
Reading start word
Data
Description
+0
0
0
1
1
Command code
Reading start word
Data
Description
+0
0
0
1
2
Command code
Содержание V530-R160E
Страница 36: ...34 SECTION 1 Operational Flow V530 R160 Operation Manual SECTION 1 Outline MEMO...
Страница 144: ...142 SECTION 5 Setting Reading Conditions QRCode V530 R160 Operation Manual SECTION 5 Setting Reading Conditions MEMO...
Страница 192: ...190 SECTION 7 Checking the Version Version V530 R160 Operation Manual SECTION 7 System Settings MEMO...
Страница 250: ...248 SECTION 8 Serial Interface Host Link V530 R160 Operation Manual SECTION 8 Communication with the Host MEMO...
Страница 288: ...286 SECTION 10 Glossary SECTION 10 V530 R160 Operation Manual SECTION 10 Appendix MEMO...