![background image](http://html1.mh-extra.com/html/omron/v530-r150/v530-r150_operation-manual_741959034.webp)
!
!
3-1
Section
Specifications
22
3-1
Specifications
3-1-1
Crimp Terminals and Cables
The terminal block uses M3 terminal screws. Use appropriate
crimp terminals for M3 screws, as shown below. Tighten the
screws to a torque of between 0.5 and 0.6 N
S
m. After wiring,
check to make sure that the wiring is correct.
WARNING
Cover the terminal blocks with the Terminal Block Protection
Covers. Uncovered terminal blocks can result in electric shock.
Forked
Round
6.2 mm max.
6.2 mm max.
Applicable wire size: Insulated wire, 1.31 to 1.65 mm
2
(AWG16
to AWG15)
3-1-2
Specifications
WARNING
Use a DC power supply with safe extra low-voltage circuits on
the secondary side. Excessively high voltage can result in
electric shock.
Input Specifications
Item
V530-R150E (NPN model)
V530-R150EP (PNP model)
Input voltage
12 to 24 VDC
±
10%
ON current
3 to 15 mA
ON voltage
8.8 V max.
OFF current
0.1 mA max.
OFF voltage
4.5 V min.
ON delay
RESET input: 10 ms max.
Others:
0.5 ms max.
OFF delay
RESET input: 15 ms max.
Others:
0.7 ms max.
Internal circuits
Input
terminal
COM IN
Input
terminal
COM IN
Содержание V530-R150
Страница 1: ...Cat No Z136 E1 1 V530 R150 OPERATION MANUAL 2 Dimensional Code Reader ...
Страница 2: ...V530 R150 2 Dimensional Code Reader Operation Manual Produced July 1999 ...
Страница 89: ...5 4 Section STEP 2 Setting Reading Conditions 79 8 Select 1 Read DataMatrix 9 Select Reading Settings ...
Страница 95: ...5 6 Section STEP 4 Starting Code Reading 85 3 Input reading trigger Reading is performed QRCode ABCDE12345 ...
Страница 132: ...6 2 Section SET Setting Mode 123 Line Bright X fixed Y coordinate Line Bright Y fixed X coordinate ...
Страница 197: ...Cat No Z136 E1 1 V530 R150 2 Dimensional Code Reader OPERATION MANUAL ...