6-5
Section
System
141
5
Select None, STX, or ESC. (Default setting: None)
6
Select CR, LF, or CR+LF. (Default setting: CR)
7
Select OFF or ON. (Default setting: OFF)
8
Select OFF or ON. (Default setting: OFF)
The number of digits are shown in bytes. A letter or a num-
ber is 1 digit.
9
Select Normal or Host link (Default setting: Normal)
Normal
If
Normal is selected for the communications mode, it is possible
to communicate with host devices such as personal computers
with normal format via RS-232C.
MON (Monitor) Mode
Receives command inputs, but the reading results are not out-
put.
RUN Mode
Possible to input commands and output the reading results.
Timeout
[ 5]s
Flow control
None
1
None:
No flow control. (Default setting)
RS/CS:
The hardware performs flow control. Use a
cable that connects the RS and CS signals of
the V530-R150 and external device. Data is
transferred when the CS signal from the exter-
nal device is ON.
Xon/off:
The software performs flow control. Data is
transferred according to the Xon/off codes from
the external device.
Содержание V530-R150
Страница 1: ...Cat No Z136 E1 1 V530 R150 OPERATION MANUAL 2 Dimensional Code Reader ...
Страница 2: ...V530 R150 2 Dimensional Code Reader Operation Manual Produced July 1999 ...
Страница 89: ...5 4 Section STEP 2 Setting Reading Conditions 79 8 Select 1 Read DataMatrix 9 Select Reading Settings ...
Страница 95: ...5 6 Section STEP 4 Starting Code Reading 85 3 Input reading trigger Reading is performed QRCode ABCDE12345 ...
Страница 132: ...6 2 Section SET Setting Mode 123 Line Bright X fixed Y coordinate Line Bright Y fixed X coordinate ...
Страница 197: ...Cat No Z136 E1 1 V530 R150 2 Dimensional Code Reader OPERATION MANUAL ...